Related Experiment Video
Updated: Jul 16, 2026

Improving IV Insulin Administration in a Community Hospital
Published on: June 11, 2012
Impact of a Hospital Information System-Integrated Automated Dispensing Cabinet on Medication Use and Safety in a
Ryang Soon Lim1,2, Woon-Jeong Lee3,4, Hyen Oh La1
1College of Pharmacy, The Catholic University of Korea, Gyeonggi-do 14662, Republic of Korea.
Abstract:
Background/Objectives: Emergency departments (EDs) are particularly prone to medication errors because of urgent treatment environments and high decision density. Automated dispensing cabinets (ADCs) integrated with the hospital information system (HIS) may improve medication safety, yet real-world evidence in centralized-pharmacy settings remains limited. This study evaluated the impact of an HIS-integrated ADC on medication use, medication errors, and nurses' perception of safety in the ED of a Korean tertiary hospital. Methods: In this prospective before-and-after study, prescribing patterns, medication storage, and related costs were compared in the two months before (Phase 1; September-October 2019) and after (Phase 2; May-June 2020) ADC installation. Medication errors reported through the hospital safety incident reporting system were analyzed over corresponding 6-month windows from July 2019 to June 2020. Long-term sustainability was assessed using follow-up data collected from October to November 2023 (Phase 3), and all 46 ED nurses completed a 5-point Likert-scale survey on perceived medication safety. Results: Daily injectable prescriptions were unchanged (221.1 ± 34.6 vs. 227.7 ± 35.2; p = 0.301), whereas returned injectable prescriptions increased (17.9 ± 5.9 vs. 25.1 ± 6.0; p < 0.001) and non-injectable prescriptions decreased (163.1 ± 42.2 vs. 140.0 ± 22.7; p < 0.001). The number of medication items stored in the ED storage room declined by 95.6%, with a 92.5% reduction in related maintenance cost. Total medication errors decreased from 41 (74.5%) before to 14 (25.5%) after implementation (p < 0.001), with the largest reduction in delivery errors (17 [30.9%] to 2 [3.6%]). These improvements were sustained at the three-year follow-up. Nurses reported high overall satisfaction with medication safety (4.27 ± 0.62 on a 5-point Likert scale). Conclusions: Implementation of an HIS-integrated ADC in the ED was associated with improved prescription patterns, fewer reported medication errors, and enhanced perceived medication safety. In addition, these improvements were sustained over time, indicating stable and consistent implementation of the ADC system. Nurses also reported improved perceptions of medication safety.
Related Concept Videos
Pharmaceutical Poisoning: Potential Scenarios
Health Information Technology and Healthcare Information System
Health Information Technology, commonly called HIT, integrates advanced information systems and technology in healthcare settings. Its primary functions include:
Nursing Clinical Information System
A Nursing Clinical Information System (NCIS) is a specialized type of healthcare information system tailored to meet the unique needs of nursing practice. It incorporates the principles of nursing informatics to streamline information management and improve the quality of care delivery.
Critical attributes of NCIS include:
Integrated Healthcare System
Pharmacovigilance
This process, termed pharmacovigilance, aims to detect, evaluate, and minimize harmful effects related to medication use. The data collection for pharmacovigilance depends on spontaneous reporting systems, where healthcare professionals or patients voluntarily report suspected ADRs.
In some cases, there...
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...