Non-invasive arterial blood pressure waveform generation in critically ill patients: A sensor-based deep learning
Carl Harris1, Bright Nnadi2, Sampath Rapuri1
1Department of Biomedical Engineering, Whiting School of Engineering, Johns Hopkins University, Baltimore, MD, United States of America; Laboratory of Computational Intensive Care Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, United States of America.
None:
Continuous monitoring of Arterial Blood Pressure (ABP) in critically ill patients requires invasive arterial catheterization, which carries risks of thrombosis, vascular injury and infection. Here, we train and validate a computational model for continuous non-invasive ABP estimation in Intensive Care Unit (ICU) patients using a novel wearable sensor array. The sensor acquires continuous high frequency photoplethysmography (PPG) and electrocardiography (ECG) signals which are used as inputs in a deep learning algorithm for beat-to-beat reconstruction of ABP waveforms. We include 28 patients enrolled in four ICU units at Johns Hopkins Hospital, comprising 15,489 5-s ECG and PPG segments. A CNN/LSTM hybrid architecture achieved an R2 of 0.732 and a mean absolute error (MAE) of 6.42 ± 3.82 mmHg, with systolic and diastolic blood pressure MAEs of 6.21 ± 3.89 and 3.41 ± 3.02 mmHg, respectively. This performance closely approached an upper-bound model trained on contemporaneously acquired ground truth ECG and PPG signals (R2=0.799, MAE=5.67 mmHg), indicating that the sensors retain most hemodynamically relevant information. Split-conformal prediction provided calibrated uncertainty intervals with coverage meeting nominal targets, offering a principled framework for bedside confidence assessment. These findings demonstrate the feasibility of accurate, continuous, non-invasive ABP waveform estimation from wearable biosignals in critically ill patients, establishing a foundation for reducing dependence on invasive arterial monitoring while preserving the waveform-level information essential for hemodynamic management.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: