Related Experiment Video For computerized tomography
Updated: Aug 6, 2026

Computer-Aided Three-Dimensional Visualization in the Treatment of Locally Advanced Thyroid Cancer
Published on: June 9, 2023
The Clinical Value of Distinguishing Benign and Malignant Thyroid Micronodules With Intratumoral and Peritumoral CT
Dan Kong1, Fen Wang1, Wenli Shan1
1Department of Imaging, The Affiliated Huaian First People's Hospital of Nanjing Medical University, Huaian.
Objective:
To study the utility of intratumoral and peritumoral radiomic models in distinguishing between benign and malignant thyroid micronodules.
Methods:
CT-enhanced images of 607 patients with thyroid micronodules were obtained, and an additional 100 patients with micronodules were collected as an independent test group on the basis of the sequence of their examination times. The peritumoral region of interest (ROI) was delineated by expanding outward by 1 and 2 mm. Radiomics features were extracted from the 3-dimensional volume of interest (VOI), which included intratumoral, peritumoral 1 mm, peritumoral 2 mm, intratumoral+peritumoral 1 mm and 2 mm in the arterial phase, venous phase, and combined arteriovenous phase. All of the data were randomly divided into training and validation groups at an 8:2 ratio. The minimum redundancy maximum relevance (mRMR) and the least absolute shrinkage and selection operator (LASSO) method was utilized for regression dimension reduction. Radscore, clinical, and combined models were constructed. A nomogram was used to assess the performance of the fusion model, and an external test group was utilized to test the model's performance.
Results:
The intratumoral+peritumoral 1 mm radiomic model based on arterial-venous phase fusion had the best prediction performance (AUC training group 0.838; 95% CI: 0.802-0.873; validation group 0.827; 95% CI: 0.755-0.899; external test group 0.770; 95% CI: 0675-0.864). The combined model constructed with the radscore and clinical model was the optimal model (AUC training group 0.859; 95% CI: 0.826-0.892; validation group 0.876; 95% CI: 0817-0.935; external test group 0.810; 95% CI: 0.723-0.897).
Conclusion:
Both the intratumoral and peritumoral radiomic models had good diagnostic efficacy in differentiating benign and malignant thyroid micronodules.