Machine learning-driven integration of 24-hour ambulatory blood pressure and its variability
Evangelos Ntalianis1, Everton Jose Santana1, Nicholas Cauwenberghs1
1Department of Cardiovascular Sciences, Research Unit Hypertension and Cardiovascular Epidemiology, KU Leuven, Leuven, Belgium.
Abstract:
Twenty-four hour ambulatory blood pressure (BP) monitoring (24-hour ABPM) is considered the best out-of-office BP measurement to assess hypertension. Yet, the complexity of the obtained data, hinders their interpretation. Therefore, in this study, we investigated whether a clustering algorithm could facilitate the integrative interpretation of 24-hour ambulatory BP and its variability to construct distinctive clusters associated with cardiovascular (CV) outcomes. In 1344 community-dwelling individuals (mean age, 46.9 years; 50.6% women), we acquired 24-hour ABPM recordings, clinical data at baseline and we collected adverse outcomes (median follow-up time 19.4 years). We used dynamic time warping combined with the k-medoids clustering algorithm on the heart rate, systolic and diastolic BP recordings. Clinical characteristics and CV outcome were used to evaluate the validity of the derived clusters using the original cohort, while an external general population cohort (n = 1219) was used for further validation. We separated the dataset into 4 clusters. Cluster 1 showed the most favourable CV risk profile comprising younger individuals with the lowest 24-hour ABPM patterns. On the contrary, cluster 4 revealed the worst CV profile with older participants, higher office and 24-hour ABPM, higher medication intake and the highest BP variability. After adjusting for traditional risk factors, including office systolic BP cluster 4 had significantly higher risk of adverse CV events compared to cluster 1 (HR: 1.63; 95%CI:1.15-2.32; P = 0.006). Similar findings were made in the external validation cohort. Time series clustering of ABPM recordings may facilitate the integrative interpretation of 24-hour ambulatory BP and BP variability.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...