Related Experiment Video
Updated: Aug 6, 2026

Quantitative Analysis by Thermogravimetry-Mass Spectrum Analysis for Reactions with Evolved Gases
Published on: October 29, 2018
Solution-Phase Energy Decomposition Analysis (SP-EDA): Theory and Applications
Gábor Paragi1,2,3, Célia Fonseca Guerra4, F Matthias Bickelhaupt4,5,6
1Institute of Physics, University of Pécs, Pécs, Hungary.
Abstract:
We present an extension of our canonical energy decomposition analysis (EDA) from the gas phase to a Solution-Phase approach (SP-EDA), that is, to interactions between molecular fragments in the condensed phase, simulated using the Conductor-like Screening Model (COSMO). To this end, we have introduced different solvation states that serve to simulate particular physical phenomena that can be associated with the step from separate solvated fragments to the solvated complex of these fragments. In addition to the well-known deformation strain of the fragments, induced by complex formation, one can distinguish the desolvation of the contact points via which the fragments bind, the response of the solvent to the deformation of the fragments as well as the response of the solvent to the formation of the complex, and finally the complex formation between the partially desolvated fragments. We provide definitions of how to model these phenomena using a continuum model, such as COSMO. Finally, we analyze, for representative model systems, how the bonding and, in particular, the EDA terms of electrostatic attraction, Pauli repulsion, and stabilizing orbital interactions behave across the above steps associated with interactions in solution. An important practical conclusion is that neglecting the effect of the partial desolvation at the binding sites has, in most cases, only minor consequences for the values and trends in the EDA terms. This finding can be used to simplify investigations using SP-EDA.
Related Concept Videos
Atomic Emission Spectroscopy: Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Electrogravimetric Analysis: Overview
To test the completeness of the...
Free Energy and Equilibrium
Recall that Q is the numerical value of the mass action expression...
Mass Spectrum: Interpretation
