Related Experiment Video
Updated: Aug 6, 2026

A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
Engineering Function-Reversal Sacrificial Sites for Selective Volatile Aromatic Hydrocarbons Detection in Complex
Zhanchen Wang1,2, Xin Jia1, Runfang Mao1
1Department of Chemistry, College of Sciences, Shanghai University, Shanghai, P. R. China.
Abstract:
Accurately monitoring carcinogenic volatile aromatic hydrocarbons (BTXs) is crucial for assessing air-qualities and danger-classes in specific occasions, However, it remains challenging to conduct highly selective identification of them in complex environments. Here, we have developed a gas-shunting strategy by installing function-reversal ZnO materials into Ir-WO3 supports to diminish interference-gas responses and guide special aromatic hydrocarbons sensing. We find that ZnO materials can serve as reactively sacrificial sites for small-molecule H2S and CO and induce main aromatic hydrocarbons reactants into Ir-WO3 supports. This gas-shunting route guarantees highly-selective aromatic hydrocarbons sensing even in dual/ternary gas mixtures. Through integrating functional-opposite sensors into a system, the final sensing arrays achieve 100% classification accuracy for 10 single gases and 75 multi-compose gases with low training costs. In addition, we also show an autonomic "cruise-detection" system by equipping sensor arrays into robotic dog to accurately identify complex gases. Our findings emphasize sensors designs with selective features and may broaden integrated sensing-system analysis in complex environment.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
11:59Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
High-Performance Liquid Chromatography: Types of Detectors
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...