Related Experiment Video
Updated: Aug 6, 2026

Calibrated Passive Sampling - Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers
Published on: March 21, 2016
Development and calibration of a passive sampler for monitoring airborne 131I in nuclear medicine facilities
Abstract:
Monitoring volatile iodine-131 (131I) in nuclear medicine is of great importance for occupational protection. Conventional active monitors require continuous power and generate noise, necessitating reliable passive alternatives. Herein, we report the development, geometric optimization, and dynamic calibration of a passive sampler tailored for airborne organic 131I (CH3131I). To maximize High-Purity Germanium (HPGe) detection efficiency while maintaining an optimal Fickian diffusion length, the sampler's geometry was optimized using LabSOCS Monte Carlo simulations. An optimal diameter-to-height ratio of 4 was established for sorbent volumes <150 mL and validated against traceable multi-gamma standards. A 12-16 mesh coconut shell activated carbon impregnated with 5 wt% KI served as the trapping matrix due to its efficient chemisorption via isotopic exchange. Applying these parameters to a 40 g carbon loading yielded a prototype featuring an 8.4 cm internal diameter, a 2.1 cm carbon depth, and a 2.3 cm effective diffusion length. Dynamic calibration in a micro-reactor under clinical conditions (26°C, 60% relative humidity) revealed a stable sampling rate (SR) of 0.030 m3 h-1 within the linear kinetic regime (≤25% EA). The SR demonstrated high thermodynamic stability across typical ward temperatures (10-26°C) with a 6.0% coefficient of variation. With a combined expanded relative uncertainty of 12.16% (k = 2), the sampler achieved a Minimum Detectable Concentration (MDC) of 0.74 Bq m-3. This work opens a new avenue for determining time-weighted average (TWA) airborne radioiodine concentrations, advancing internal dosimetry protocols.
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Emission Spectroscopy: Instrumentation
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Emission Spectroscopy: Lab

