Related Experiment Video
Updated: Aug 6, 2026

03:07
Single-Port Robotic-assisted Transaxillary Breast-conserving Surgery: A Prospective, Single-arm, Non-randomized Phase IIa Clinical Trial
Published on: August 19, 2025
Randomized double-blind protocol for cross-specialty competency assessment in robotic surgery training using GEARS: a
Huiqin Zhou1, Yuxuan Zheng2, Yujun Peng3
1Second Clinical College, Hospital of Wuhan University, Wuhan, Hubei Province, China.
Journal of Robotic Surgery
|July 20, 2026
Summary
The Global Evaluative Assessment of Robotic Skills (GEARS) system effectively assesses surgical trainee competency across specialties. This randomized, double-blind study validates GEARS as a reliable tool for robotic surgery training evaluation.
Area of Science:
- Medical Education
- Surgical Technology
- Competency Assessment
Background:
- Robotic surgery training requires standardized, objective assessment methods.
- Existing cross-specialty competency evaluations for robotic surgery are limited.
- The Global Evaluative Assessment of Robotic Skills (GEARS) offers a potential framework.
Purpose of the Study:
- To evaluate the discriminatory validity of a randomized, double-blind protocol using the GEARS scoring system.
- To assess the reliability and consistency of the GEARS-based assessment in robotic surgery training.
- To determine the system's effectiveness in distinguishing trainee skill levels across surgical specialties.
Main Methods:
- Prospective, randomized, double-blind evaluation of 49 surgical trainees across general surgery, urology, and gynecology.
- Training involved simulator (dV-Trainer) and porcine models, followed by clinical observation.
- Anonymized operation videos were scored by blinded expert reviewers using the GEARS system, with internal controls for calibration.
Main Results:
- The GEARS-based protocol demonstrated good validity (KMO=0.836) and reliability (Cronbach's α=0.765).
- The system effectively distinguished trainees from experts in both simulator and live tissue operations (p<0.05).
- The assessment showed stability across specialties, training models, and sexes, with no significant differences in live tissue performance based on trainee age.
Conclusions:
- The randomized, double-blind GEARS assessment protocol is a valid and reliable tool for evaluating robotic surgery trainee competency.
- The system objectively differentiates operational abilities, supporting its use as a standardized assessment for heterogeneous robotic surgery training programs.
- GEARS has the potential to enhance the quality and consistency of surgical training evaluations.