Related Experiment Video
Updated: Aug 6, 2026

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Preclinical PET characterization of [68Ga]Ga-EMP-100 for non-invasive assessment of c-Met in NSCLC
Timofei Rusu1,2, Anita Rodenas2,3, Leo Capet2
1Laboratoire d'Imagerie Moléculaire Positonique (LIMP), UMS28 Phénotypage du petit animal, Sorbonne Universite, Paris, France.
Background:
The c-Met receptor is a key therapeutic target in non-small cell lung cancer (NSCLC). Current methods for assessing c-Met level, are limited by biopsy sampling, which fails to account for spatio-temporal and intra-tumour heterogeneity. This study aims to evaluate the use of PET/CT imaging for non-invasive, full-body quantification of c-Met expression in different subtypes of NSCLC, encompassing both ADC and squamous cell carcinoma and compare it to MET gene alterations and IHC c-Met scoring.
Results:
[68Ga]Ga-EMP-100, a PET radiotracer targeting c-Met, was radiolabelled and characterized. Cell-Derived Xenograft (CDX) models of NSCLC with different characteristics were developed and validated for PET/CT imaging using [68Ga]Ga-EMP-100. Tumour uptake and heterogeneity were quantified and compared to c-Met expression determined by IHC (H-score using SP44 and EP1454Y antibodies) and MET gene amplification detected by FISH and NGS. Automated radiolabelling of [68Ga]Ga-EMP-100 demonstrated a high radiochemical yield (RCY) and purity (RP). Pharmacokinetics studies revealed rapid excretion predominantly by the renal pathway. PET/CT imaging resulted in high contrast and enabled non-invasive classification of CDX models regarding c-Met receptor levels. The highest tumour uptake was observed in H1648 and EBC-1 models. Although MET gene alterations were not correlated with c-Met protein expression at the cell surface, a good correlation was found between SUVmax and c-Met expression, when using the EP1454Y antibody.
Conclusion:
PET/CT imaging using [68Ga]Ga-EMP-100 successfully quantified c-Met expression in vivo, clearly adding up to conventional IHC and genetic methods. Our study adds novel comparative evidence across tumour histotypes, providing new insight into how tumour phenotype affects c-Met-targeted imaging. This radiotracer holds potential as a non-invasive tool for selecting patients for c-Met-targeted therapies and monitoring therapeutic response in NSCLC. Further clinical studies are warranted.
Insights
Positron emission tomography/computed tomography (PET/CT) imaging with [68Ga]Ga-EMP-100 offers a non-invasive method for quantifying c-Met expression in non-small cell lung cancer (NSCLC). This approach aids in patient selection for c-Met-targeted therapies and monitoring treatment response.
Area of Science:
- Oncology
- Medical Imaging
- Molecular Biology
Background:
- The c-Met receptor is a critical therapeutic target in non-small cell lung cancer (NSCLC).
- Current assessment methods for c-Met levels, such as biopsy, are limited by heterogeneity.
- There is a need for non-invasive methods to quantify c-Met expression across the entire body.
Purpose of the Study:
- To evaluate PET/CT imaging using the novel radiotracer [68Ga]Ga-EMP-100 for non-invasive quantification of c-Met expression in NSCLC.
- To compare PET/CT imaging results with conventional methods like immunohistochemistry (IHC) and gene alteration analysis (FISH, NGS).
- To assess c-Met expression in different NSCLC subtypes, including adenocarcinoma (ADC) and squamous cell carcinoma.
Main Methods:
- Development and characterization of the c-Met-targeting PET radiotracer [68Ga]Ga-EMP-100.
- Establishment and validation of NSCLC Cell-Derived Xenograft (CDX) models for PET/CT imaging.
- Quantification of tumour uptake and heterogeneity using PET/CT and comparison with IHC (SP44, EP1454Y antibodies) and FISH/NGS for MET gene amplification.
Main Results:
- Automated radiolabelling yielded high radiochemical yield and purity for [68Ga]Ga-EMP-100.
- PET/CT imaging provided high contrast and enabled non-invasive classification of c-Met levels in CDX models.
- A good correlation was observed between SUVmax and c-Met expression (EP1454Y antibody), while MET gene alterations did not correlate with cell surface c-Met protein levels.
Conclusions:
- [68Ga]Ga-EMP-100 PET/CT imaging successfully quantified in vivo c-Met expression, complementing IHC and genetic methods.
- The study provides novel comparative data across NSCLC histotypes, highlighting the impact of tumor phenotype on c-Met-targeted imaging.
- This radiotracer shows potential for non-invasive patient selection and therapeutic response monitoring in NSCLC, warranting further clinical investigation.
More Related Videos
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...

