Related Experiment Video
Updated: Aug 6, 2026

A Novel Approach for the Administration of Medications and Fluids in Emergency Scenarios and Settings
Published on: November 9, 2016
Analysis of ready-to-administer medications versus conventional preparation in a simulation setting
Amelia Deacon1, Stella Cao2, Rubiya Khanom2
1Strategic Value Lead, B. Braun Medical Ltd.
Background/Aims:
This study evaluated the time efficiency, waste generation and nursing experience associated with ready-to-administer (RTA) intravenous (IV) medications compared with conventional ampoule-based preparation in a simulated environment.
Methods:
An observational time and motion study was conducted in a simulated NHS environment with 50 registered nurses. Participants completed eight preparation tasks across RTA and conventional methods at varying complexity levels. Waste was quantified, and qualitative data were collected via structured questionnaire.
Results:
RTA Ecoflac® plus infusions reduced preparation time by 50-62% (mean 82 s versus 163-214 s; P<0.05) and required 63-70% fewer components. RTA syringe preparation achieved 6-25% time savings. Nurses rated pre-prepared products as significantly easier to use (82%), time saving (92%), and associated with lower contamination risk (96%).
Conclusion:
RTA IV medications offer consistent efficiency, safety and environmental benefits over conventional preparation, with advantages scaling with preparation complexity.
Implications For Practice:
Adoption of RTA formulations could free meaningful nursing capacity for direct patient care, reduce medication errors and support sustainability objectives in clinical practice.
Related Concept Videos
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant, half-life,...
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
Dosage Interval and Administration Route: Determination Methods
Dosage Regimens: Designs and Approaches