Background:
Accurate assessment of lung volumes is essential for diagnosing ventilatory defects and managing pulmonary diseases such as interstitial lung diseases (ILDs) and chronic obstructive pulmonary disease (COPD). Although body plethysmography is the standard method, it can be limited by patient tolerance and complexity. Helium dilution method (HDM) is a portable and cost-effective alternative, while chest computed tomography (CT) offers noninvasive volume assessment through imaging. This study aimed to evaluate the agreement and potential interchangeability between TLC values measured by CT (TLCCT) segmentation and the TLCHDM in patients with ILD and COPD.
Materials And Methods:
In this retrospective study, patients who underwent HDM and chest CT were evaluated. Based on pulmonary function tests (PFTs), patients were grouped as having restrictive or obstructive ventilatory defects. TLCCT and HDM were compared using Bland-Altman analysis to assess agreement and bias.
Results:
The study included 213 patients. In the overall cohort, TLCCT was slightly lower than TLCHDM (mean difference = -0.32 L, 95% confidence interval [CI] -0.50 to -0.14 L, P = 0.0007). In subgroup analyses, the mean bias was -0.67 L (95% CI -0.84 to -0.51 L, P < 0.001) for ILD and +0.78 L (95% CI 0.35-1.21 L, P = 0.0007) for COPD, indicating underestimation and overestimation by CT, respectively. The overall 95% limits of agreement ranged from -3.0 to +2.25 L.
Conclusion:
Both HDM and CT provide valuable lung volume data. CT may serve as a reliable alternative in patients unable to undergo PFTs. Prospective studies are warranted to confirm clinical utility.
More Related Videos
08:05Lung CT Segmentation to Identify Consolidations and Ground Glass Areas for Quantitative Assesment of SARS-CoV Pneumonia
Published on: December 19, 2020
03:38Unilateral Lung Volume Analysis Using Micro-CT for Enhanced Assessment of Pulmonary Fibrosis in Preclinical Models
Published on: June 20, 2025
Related Concept Videos
Lung Capacity
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...