Related Experiment Video
Updated: Aug 6, 2026

06:10
Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
Microaxial Flow Pump Support as a Bridge to Transaxillary TAVI-In-TAVI in Cardiogenic Shock
Matteo Orlandi1, Niccolò Ciardetti2, Lucrezia Biagiotti1
1Department of Experimental and Clinical Medicine University of Florence Florence Italy.
Clinical Case Reports
|July 24, 2026
Summary
A patient with a degenerated transcatheter aortic valve received temporary mechanical circulatory support. This intervention stabilized the patient, allowing for a successful transaxillary TAVI-in-TAVI procedure.
Area of Science:
- Cardiovascular Medicine
- Interventional Cardiology
- Medical Devices
Background:
- Degeneration of transcatheter aortic valves (TAV) can lead to severe complications.
- Cardiogenic shock is a life-threatening condition requiring immediate intervention.
Purpose of the Study:
- To describe a case of cardiogenic shock caused by a degenerated TAV.
- To present a staged transaxillary TAVI-in-TAVI procedure as a treatment option.
Main Methods:
- Initiation of temporary mechanical circulatory support using a transvalvular microaxial flow pump.
- Performance of a staged transaxillary TAVI-in-TAVI (transcatheter aortic valve implantation in transcatheter aortic valve implantation) procedure.
Main Results:
- Rapid stabilization of the patient's cardiogenic shock after mechanical circulatory support.
- Favorable outcome following the staged transaxillary TAVI-in-TAVI procedure.
Conclusions:
- Temporary mechanical circulatory support is effective for stabilizing patients with acute valve degeneration.
- Transaxillary TAVI-in-TAVI is a viable treatment for degenerated TAV, offering a favorable outcome.
Related Concept Videos
Aortic Regurgitation III: Medical Management
Aortic regurgitation (AR) is when the aortic valve does not close or seal properly, leading to backward blood circulation from the aorta into the left ventricle during diastole. Common causes of AR include rheumatic heart disease, congenital valve defects, and aortic root dilation. Managing AR requires a multifaceted approach to alleviate symptoms, preserve left ventricular function, and address the underlying cause of the regurgitation. Patients with symptomatic AR or significant left...
Aortic Regurgitation I: Introduction
IntroductionAortic regurgitation is characterized by the backward flow of blood from the aorta into the left ventricle during diastole and arises from the improper closure of the aortic valve. This condition results in left ventricular volume overload and can stem from both acute and chronic etiologies, each contributing uniquely to the disease's progression and symptomatology.Acute and Chronic CausesAcute aortic regurgitation often results from events that suddenly impair the integrity of the...
Aortic Regurgitation IV: Nursing Management
A nurse managing a patient with aortic regurgitation begins with a comprehensive assessment, including a review of the patient's medical history, family history, and lifestyle factors. During the cardiac examination, the nurse listens for heart sounds and checks for signs of valve abnormalities. The nurse also observes for symptoms such as dyspnea, orthopnea, and paroxysmal nocturnal dyspnea and assesses the patient's endurance and daily activity tolerance.Based on the findings, the nurse...