Related Experiment Video
Updated: Aug 6, 2026
![Automated Preparation of [68Ga]Ga-3BP-3940 on a Synthesis Module for PET Imaging of the Tumor Microenvironment](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F68356.jpg&w=3840&q=50)
Automated Preparation of [68Ga]Ga-3BP-3940 on a Synthesis Module for PET Imaging of the Tumor Microenvironment
Published on: April 25, 2025
Phase I/IIa clinical trial of 68Ga-PSMA-11 synthesized by a newly developed automated module using
Shigeyasu Sugawara1, Shozo Okamoto2, Noriko Kanno2
1Advanced Clinical Research Center, Fukushima Medical University, 1 Hikarigaoka, Fukushima, Japan. shige-s@fmu.ac.jp.
Objective:
This Phase I/IIa study evaluated the safety, pharmacokinetics, internal radiation dosimetry, and image quality of cyclotron-produced ⁶⁸Ga-PSMA-11 synthesized using an automated module in a Japanese population.
Methods:
In this single-center trial, nine Japanese men (3 healthy volunteers, 6 prostate cancer patients) received a single intravenous injection of ⁶⁸Ga-PSMA-11 (4.0 MBq/kg). Safety, pharmacokinetics (blood/urine), and internal radiation dosimetry (serial PET/CT) were assessed. Diagnostic performance was evaluated by lesion detection rates and image quality by quantitative metrics, including noise-equivalent count (NEC), to optimize the protocol.
Results:
No adverse events were observed. The automated synthesis process consistently yielded high-quality ⁶⁸Ga-PSMA-11, with a decay-corrected radiochemical yield of 2841 ± 584 MBq and a radiochemical purity > 99%. The kidneys received the highest absorbed dose, with an effective dose comparable to that reported in published data. The agent demonstrated rapid clearance, primarily via renal excretion (58.99% ± 11.34% in 6 h), with a biological half-life of approximately 3.8 h in whole blood. All histopathology-confirmed primary lesions were detected. Quantitative analysis indicated that high image quality was maintained even with substantially reduced acquisition times.
Conclusions:
Cyclotron-produced ⁶⁸Ga-PSMA-11 is safe and exhibits favorable pharmacokinetics and dosimetry in a Japanese population. This exploratory Phase I/IIa trial suggests that the production method appears feasible.
Trial Registration:
jRCT2022230014.