Related Experiment Video
Updated: Aug 5, 2026

Tracking Fibrinolysis of Chandler Loop-Formed Whole Blood Clots Under Shear Flow in An In-Vitro Thrombolysis Model
Published on: April 19, 2024
Real-Time Fibrinolysis Monitoring of Plasma Annular Clots
Andres Prieto Trujillo1, Anushri Umesh1,2, Abigail Hall1
1Department of Emergency Medicine, Indiana University School of Medicine, 635 Barnhill Dr. Rm. 2063, Indianapolis, IN 46202, USA.
None:
Fibrinolysis assessment is critical for diagnosing and managing clinical blood disorders. Currently available viscoelastic testing platforms provide an overview of global coagulation and fibrinolysis profiles but lack fibrinolysis specific assessment of a preformed clot substrate. The lack of a sensitive, standardized testing platform for fibrinolysis assessment can limit risk stratification and the management of blood disorders. We describe herein the plasma annular clot lysis assay. The assay adapts the previously standardized FITC-tagged fibrin annular clot assay to plasma obtained from healthy human donors. Plasmin at concentrations ranging from 200-800 nM was used as a direct thrombolytic to assess fibrinolysis in plasma-derived annular clots. The Maximum Fibrinolysis Rate (VMFR), FLU200, T90, and MaxFLU were calculated via tracking of the clot digestion curve over time. VMFR was correlated with plasma thromboelastography (TEG) parameters to compare with the global viscoelastic testing system. Additionally, plasma annular clot digestion was monitored in the presence of pentamidine to assess drug-specific effects on fibrinolysis tracking. Plasma annular clots linearly tracked fibrinolysis with increasing plasmin concentration. VMFR across multiple tested plasmin concentrations showed a moderate to strong negative correlation (0.58-0.74) with the observed maximum amplitude from plasma TEG. In the presence of pentamidine (75 µM), the assay was sensitive to identifying differences in the VMFR across treatment groups. Plasma annular clots provide a platform for fibrinolysis evaluation using a patient's own plasma to assess therapeutic dosing clinically in addition to testing novel therapeutics preclinically to further understand mechanistic aspects of fibrinolysis.
More Related Videos
07:09Experimental and Imaging Techniques for Examining Fibrin Clot Structures in Normal and Diseased States
Published on: April 1, 2015
09:38A Microfluidic Flow Chamber Model for Platelet Transfusion and Hemostasis Measures Platelet Deposition and Fibrin Formation in Real-time
Published on: February 14, 2017
Related Concept Videos
Clot Retraction and Fibrinolysis
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Venous Thrombosis III: Interprofessional Care