Negative Predictive Value of Allergologic Work-Up with Iodinated Contrast Media in 'Real-Life' Practice
Krzysztof Specjalski1, Ilona Iwaszko1, Dominik Typiak1
1Department of Allergology, Medical University of Gdańsk, ul. Smoluchowskiego 17, 80-952 Gdańsk, Poland.
Allergologic work-up, including skin prick tests (SPTs) and drug provocation tests (DPTs), effectively identifies safe iodinated contrast media (ICM) for patients with prior hypersensitivity reactions. This approach demonstrates a high negative predictive value in real-world settings.
Area of Science:
- Allergy and Immunology
- Radiology and Imaging
Background:
- Iodinated contrast media (ICM) hypersensitivity reactions necessitate strategies for safe administration.
- Premedication and allergologic work-up are common approaches to mitigate risks.
- Real-world data on the predictive value of these diagnostic methods is crucial.
Purpose of the Study:
- To evaluate the negative predictive value of skin tests and comprehensive allergologic work-up for iodinated contrast media (ICM).
- To determine the safety of ICM application in patients with a history of hypersensitivity reactions.
Main Methods:
- Retrospective enrollment of 210 patients with prior ICM hypersensitivity.
- Stepwise protocol involving skin prick tests (SPTs), intracutaneous tests (ICTs), and intravenous drug provocation tests (DPTs).
- Telephone follow-up at least 6 months post-testing to assess outcomes.
Main Results:
- Skin tests (SPT/ICT) and DPTs identified safe ICMs in 87% of patients.
- Negative predictive value of skin tests relative to DPTs was 95%.
- Overall allergologic work-up showed a 90% negative predictive value in real-life settings, with 41% of patients receiving recommended ICMs.
Conclusions:
- Skin tests and DPTs possess high negative predictive value for determining safe ICMs.
- Allergologic work-up is effective in identifying safe ICMs for the majority of patients with hypersensitivity history.
- These diagnostic tools facilitate safer ICM administration in clinical practice.