Thermo-Mechanical Characterization of GFRP Molded Grating Composites Exposed to Elevated Temperatures
Emrah Madenci1,2, Muhammed İhsan Özgün3, Ceyhun Aksoylu4
1Department of Civil Engineering, Necmettin Erbakan University, 42090 Konya, Türkiye.
None:
This study comprehensively investigates the thermal and mechanical degradation behavior of molded glass-fiber-reinforced plastic (GFRP) grating composites subjected to temperatures ranging from 80 °C to 320 °C. Three types of industrially produced GFRP gratings-open-type (OG), thin closed-skin (CG), and thick closed-skin (TCG)-were evaluated using mechanical, microstructural, chemical, and crystallographic analyses. Three-point bending tests revealed that TCG-type specimens exhibited superior thermal resistance, experiencing only a 43.9% loss in strength at 320 °C, whereas OG-type specimens showed significant resin degradation, fiber-matrix decomposition, and microcrack formation at temperatures above 200 °C. Scanning Electron Microscopy (SEM) and Fourier Transform Infrared Spectroscopy (FTIR) analyses revealed significant resin degradation, fiber-matrix decomposition, and microcrack formation. Thermogravimetric analysis (TGA) and Differential Scanning Calorimetry (DSC) confirmed substantial mass loss and structural disintegration at temperatures above 200 °C. Dynamic Mechanical Analysis (DMA) results revealed that the glass transition temperature (Tg) occurred at approximately 115-120 °C. The second-order regression model developed to estimate flexural strength under increasing temperature provided high accuracy (R2 > 0.99) for all grating types. It should be noted that this investigation focuses on the short-term thermo-mechanical response under fundamental flexural loading to provide an accurate baseline for preliminary engineering design. The findings emphasize that the effect of temperature should be considered a critical parameter in the structural design of GFRP systems, especially in industrial environments with temperatures above 120 °C. Accordingly, tables for material selection and load-carrying capacity should be recalibrated to account for short-term temperature effects.
More Related Videos
09:54Measuring the Mechanical Properties of Glass Fiber Reinforcement Polymer Composite Laminates Obtained by Different Fabrication Processes
Published on: June 30, 2023
10:52Conducting Elevated Temperature Normal and Combined Pressure-Shear Plate Impact Experiments Via a Breech-end Sabot Heater System
Published on: August 7, 2018
Related Concept Videos
Thermal Strain
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55 °C.
