Temperature Effect on Residual Magnetic Field of Atomic Gyroscope Magnetic Shielding System: A High-Precision
Yitao Chen1, Junzhong Li2, Shengxin Lin1
1School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin 150001, China.
Abstract:
The residual magnetic field of the magnetic shielding system is a key factor limiting the bias stability of high-precision atomic gyroscopes. Due to the temperature dependence of hysteresis in soft magnetic materials, variations in ambient temperature can cause drift in the residual magnetic field inside the shielding cavity, thereby introducing measurement errors. Existing studies mostly rely on time-consuming finite element methods (FEM), which struggle to efficiently characterize the temperature-magnetic coupling effect. To address this issue, this paper develops a theoretical model for a fast solution. First, a static magnetic field analytical model for the multilayer cylindrical magnetic shielding system is established. Second, nonlinear magnetization theory is introduced to correct the calculation errors caused by the nonlinear variation in material permeability under weak fields. On this basis, an improved Jiles-Atherton (J-A) model incorporating a temperature correction factor is constructed to accurately characterize the magnetic field distribution inside the shielding system at different temperatures. The results demonstrate that the proposed analytical model can independently and rapidly predict the residual magnetic field distribution at different temperatures, without requiring any calibration or fitting based on FEM simulations. After accounting for hysteresis nonlinearity, the deviation of the shielding factor at the center point between the analytical model and FEM simulations is approximately 5%. The static residual magnetic field at the center point exhibits a negative correlation with temperature variation. Within the actual operating temperature range of the atomic gyroscope from -40 °C to 60 °C, the measured results agree with the model predictions regarding the temperature-dependent trend of the radial residual magnetic field. The relative deviation of the radial residual magnetic field ranges from 2.78% to 7.69%, and that of the axial residual magnetic field ranges from 7.94% to 14.47%, thereby verifying the accuracy of the theoretical model. This model effectively predicts the residual magnetic field drift law of the magnetic shielding system under varying temperature conditions and can provide theoretical support for the analysis and active compensation of thermally induced magnetic errors in atomic gyroscopes.
Related Concept Videos
Diamagnetic Shielding of Nuclei: Local Diamagnetic Current
Magnetic Damping
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
Atomic Nuclei: Larmor Precession Frequency
Magnetic Field due to Moving Charges
Consider a point charge moving with a constant velocity. Like the electric field, the magnetic field at any point is directly proportional to the magnitude of the charge and inversely proportional to the square of the distance between the source point and the field point. However, unlike the electric field, the magnetic field is always perpendicular to the plane containing the line...
Magnetic Field of a Solenoid
Consider a solenoid with 100 turns wrapped around a cylinder of...
Atomic Nuclei: Nuclear Relaxation Processes