Related Experiment Video
Updated: Aug 5, 2026

Multicolor Fluorescence Detection for Droplet Microfluidics Using Optical Fibers
Published on: May 5, 2016
A Multispectral Pulsed-Transmission Laser-Diode Sensor Concept for Real-Time In Situ Assessment of Microplastics in
Georgi V Vladimirov1, Ekaterina Iordanova1, Georgi Yankov1
1Georgi Nadjakov Institute of Solid-State Physics, Bulgarian Academy of Sciences, 1784 Sofia, Bulgaria.
Abstract:
Microplastic monitoring needs methods that operate directly in water with minimal sample handling. Conventional techniques such as infrared and Raman spectroscopy and pyrolysis-GC/MS provide polymer-specific information but require sample preparation and delayed laboratory analysis. We propose an optical sensor concept for real-time, in situ microplastic assessment, based on multispectral pulsed transmission in the visible range using synchronized laser-diode lines and the directly transmitted signal through an active sensor volume. After calibration on particle-free water, each particle event reduces to a water-normalized transmission whose deficit is set by geometrical beam-particle overlap and the wavelength-dependent extinction efficiency. The weak polymer absorption is represented by the Urbach-tail formalism, the refractive-index-related redirection of light by a Fresnel-based, surface- and orientation-averaged probability of direct transmission, and particle size and shape are decoupled through an effective optical length. The coupled nonlinear system is solved for the bounds of the polymer absorption coefficient per candidate geometry. Because each polymer occupies a bounded region in multi-wavelength absorption space fixed by its band gap and structural state, the method can, in principle, separate structural modifications of identical composition, such as low- and high-density polyethylene. This is a sensor concept with a model-based proof of concept, not full environmental validation. Experimental verification on real reference particles is reported separately; the present article establishes the measurement model and inversion scheme that this verification builds on.
More Related Videos
06:46Pulsed Laser Diode-Based Desktop Photoacoustic Tomography for Monitoring Wash-In and Wash-Out of Dye in Rat Cortical Vasculature
Published on: May 30, 2019
13:38Laser-Induced Fluorescence Emission (L.I.F.E.) as Novel Non-Invasive Tool for In-Situ Measurements of Biomarkers in Cryospheric Habitats
Published on: October 26, 2019