Related Experiment Video
Updated: Aug 5, 2026

Conducting Maximal and Submaximal Endurance Exercise Testing to Measure Physiological and Biological Responses to Acute Exercise in Humans
Published on: October 17, 2018
Cooper's 12 Minute Run Systematically Underestimates VO2 max in Collegiate Team Sport Athletes: Validity and
Edgard Mkvk Soares1,2, Robson Silva2,3, Carlos Jg da Cruz2,4
1Department of Health and Human Physiological Sciences, Skidmore College, Saratoga Springs, NY, USA.
None:
The Cooper 12-Minute Run Test (CT12) is widely used to estimate cardiorespiratory fitness (CRF), yet its validity in collegiate team-sport athletes remains uncertain. This study aimed to compare the CT12-estimated VO2 max with laboratory-measured VO2 max and evaluate CT12's accuracy in classifying CRF levels. Seventy-three varsity athletes (38% women; age 21.6 ± 2.8 y; BMI 23.5 ± 3.3 kg/m2) completed CT12 on a 400-m track and a ramp-incremental treadmill test with breath-bybreath gas analysis, 2-7 days apart in randomized order. VO2 max was classified by age/sex criteria. Agreement statistics included paired tests, Pearson correlation, Bland-Altman bias, and 95% limits of agreement (LOA), 95% confidence intervals (CI), and diagnostic indices (sensitivity, specificity, positive/negative predictive value) for detecting good, excellent, and superior CRF. Field (soccer/rugby) and court (futsal/handball) subgroups were analyzed. CT12 on average underestimated VO2 max by 6.0 mL(kg.min)-1 (p<0.001; r=0.69), with wide LOA: -19.8 to +7.9 mL(kg.min)-1. CT12's sensitivity to identify good or better CRF was low (58% [95% CI 45-69%]). However, it demonstrated superior specificity (86% [95% CI 60-96%]) and exhibited an excellent positive predictive value of 94% (95% CI 82-99%). Similar patterns were observed for classifications of excellent and superior CRF. We conclude that in collegiate team-sport athletes, CT12 underestimates VO2 max with substantial individual error. Nevertheless, a positive CT12 classification (good/excellent/superior) is trustworthy due to high specificity/PPV, whereas a negative result warrants further evaluation. These findings endorse CT12 as a practical screening instrument for elevated CRF levels, rather than a replacement for laboratory VO2 max when precise measurement is essential.
More Related Videos
Related Concept Videos
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Compacting Factor test
The procedure begins by placing concrete into the upper hopper without any compaction. Once filled, the bottom door of this hopper is opened,...
Exercise and Muscle Performance
Endurance exercises
Endurance exercises involve running, swimming, or cycling, which require repetitive movements with low force output. When a person engages in endurance exercise, a few noticeable changes occur in their skeletal muscles. For instance, the number of capillaries...

