Related Experiment Video
Updated: Aug 5, 2026

Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
ECG-Based Artificial Intelligence for Classifying Left Ventricular Dysfunction and Heart Failure With Preserved
Ibrahim Karabayir1, Olivia Gilbert1, Ali Valika2
1Department of Cardiovascular Medicine Wake Forest School of Medicine Winston-Salem NC USA.
Background:
Left ventricular (LV) dysfunction and heart failure with preserved ejection fraction (HFpEF) often present with early signs that are frequently overlooked or attributed to other conditions. This study proposes a novel, externally validated artificial intelligence (AI) tool using ECG data (ECG-AI) for the simultaneous detection of subtypes of LV dysfunction and HFpEF.
Methods:
Two ECG-AI models, using 12-lead or single-lead ECG, were developed using data from Atrium Health Wake Forest Baptist and University of Tennessee Health Science Center (UTHSC) to classify ECGs into 4 categories: reduced LV ejection fraction (rEF; EF<40), midrange EF (mEF; 40≤mEF<50), HFpEF, and controls (no LV dysfunction or HFpEF). Next, a boosting algorithm was used to incorporate clinical risk factors. Finally, the models were independently validated on pediatric data from UTHSC.
Results:
The Atrium Health Wake Forest Baptist cohort included 1 078 198 digital ECGs from 165 243 patients (5% rEF, 8% mEF, 2% HFpEF), and the UTHSC external validation cohort comprised 72 832 ECGs from 42 880 patients (1% rEF, 1% mEF, 1% HFpEF). For the 12-lead (Lead-I) ECG-AI model, areas under the curve for rEF/mEF/HFpEF were 0.90/0.81/0.80 (0.89/0.78/0.75) in the Atrium Health Wake Forest Baptist holdout data and 0.92/0.76/0.73 (0.90/0.75/0.74) in the UTHSC data. Clinical data-only machine-learning models lacked generalizability; clinical + ECG-AI models did not show any significant improvement compared with ECG-alone models. With 8418 ECGs (142 cases, 8276 controls) from UTHSC pediatric data, the 12-lead model achieved areas under the curve of 0.97/0.71/0.64 for rEF/mEF/HFpEF, and the Lead I model had areas under the curve of 0.94/0.77/0.67.
Conclusions:
ECG-AI can accurately detect LV dysfunction and HFpEF even from single-lead ECG, enabling potential low-cost screening.
Related Concept Videos
Heart Failure IV: Classification and Diagnostic Evaluation
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Heart Failure II: Pathophysiology
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...