Related Experiment Video
Updated: Aug 5, 2026

Automated Hospital Room Disinfection Utilizing a Novel Aerosolized Hydrogen Peroxide Microdroplet Disbursing Technology
Published on: February 24, 2026
Implementation of a novel modality for manual high-level disinfection of ultrasound probes: User perceptions and
Kathleen McMullen1, Steve Kovak1, Sean Balagna2
1Mercy Quality and Safety Center, Chesterfield, MO.
Background:
Chlorine dioxide (ClO2) foam is a novel modality for performing manual high-level disinfection (HLD) of ultrasound probes used in semi-critical health care procedures. Two midwestern health care systems implemented the compound at 29 clinical ultrasound locations. This study was undertaken to understand users' perceptions of ClO2 and ability to follow application requirements.
Methods:
User perceptions were evaluated using electronic surveys, one given to leadership, the other to users of the product, in September 2025. During October-November 2025, infection preventionists (IPs) evaluated compliance with application requirements through observations in 15 locations, using a checklist matching the manufacturer's instructions for use (IFUs).
Results:
The surveys were completed by 12 leaders and 57 users, yielding 54% and 33% response rates, respectively. Survey results were very positive overall, with agreement about adequate training resources, staff competencies, and physical environment. IPs completed 65 observations of compliance with application requirements, averaging 4.3 observations per study site. The most common deviation from the IFUs was failure to use protective eyewear (27, 41%).
Conclusions:
The user surveys revealed high approval of manually applied ClO2 foam for HLD of ultrasound probes. IP observations of routine use similarly confirmed the reliability of the steps required by the manufacturer's IFUs.
Related Concept Videos
Hand hygiene
Hand washing...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration