Related Experiment Video
Updated: Aug 13, 2026

Simplified Intrafemoral Injections Using Live Mice Allow for Continuous Bone Marrow Analysis
Published on: November 10, 2023
Systemic Lead Poisoning Secondary to Retained Intra-articular Bullet: A Case Report
Damon Dunwody1, Jack Lambert1, Andrew Register1
1Georgia Orthopedic Trauma Institute, Mercer University School of Medicine, Macon, Georgia.
Case:
A 49-year-old man presented with confusion, hallucinations, and seizure-like episodes. Evaluation revealed severe anemia and knee imaging showed lead synovitis from a gunshot wound received 27 years previously. Substance-related causes initially complicated the clinical picture, but further testing identified a critically elevated blood lead level. The patient was treated with chelation therapy and surgery to remove a retained bullet fragment and inflamed, metal-stained synovial tissue. After treatment, his mental status normalized and blood lead levels steadily declined.
Conclusion:
This case highlights that retained intra-articular bullets can cause severe lead poisoning decades later, requiring early recognition and combined medical/surgical management.