Related Experiment Video
Updated: Aug 5, 2026

Human Fetal Blood Flow Quantification with Magnetic Resonance Imaging and Motion Compensation
Published on: January 7, 2021
3D VISUALISATION AND VOLUMETRIC ASSESSMENT OF THE FETAL LARGE BOWEL ACROSS GESTATION USING MRI: A PILOT
Anangsha Kumar1, Alice Doyle2, Anastasija Arechvo1
1Department of Women and Children's Health, School of Life Course and Population Sciences, King's College London; Fetal Medicine Research Institute, King's College Hospital, London.
This study introduces a 3D MRI technique for fetal large bowel volumetry, showing it is reproducible and feasible. This method allows for accurate measurement of fetal bowel development, aiding in the antenatal detection of abnormalities.
Area of Science:
- Medical Imaging
- Fetal Medicine
- Gastroenterology
Background:
- Antenatal assessment of fetal bowel is challenging with current ultrasound limitations.
- Fetal MRI has been used, but 2D measurements lack comprehensive data, and advanced 3D techniques are emerging.
- Motion-corrected 3D MRI enables high-resolution analysis of fetal abdominal structures.
Purpose of the Study:
- To apply advanced 3D MRI techniques for fetal large bowel visualization and quantification.
- To generate high-resolution datasets for volumetric assessment of the fetal large bowel.
- To establish reference ranges for fetal large bowel volume throughout gestation.
Main Methods:
- Fetal MRI (3T, T2-weighted) was performed on 40 fetuses (16-38 weeks' gestation).
- Motion-correction pipelines created 3D reconstructions of the fetal abdomen and large bowel.
- Manual segmentation of five large bowel regions allowed for volumetric measurements and reproducibility assessment (ICC).
Main Results:
- The entire fetal large bowel was visualized in 100% of the 40 analyzed datasets.
- Intra- and inter-observer agreement for measurements were good to excellent.
- Fetal large bowel volume demonstrated a linear increase with gestational age, from 1266 cm³ at 18 weeks to 13,550 cm³ at 38 weeks.
Conclusions:
- 3D reconstruction and volumetric assessment of the fetal large bowel are feasible and reproducible.
- This advanced MRI technique enhances understanding of normal fetal bowel development.
- It holds potential for improved antenatal identification of fetal bowel pathologies.