Absolute quantification of synthetic DNA fragments spanning hundreds to thousands of base pairs using SEC coupled
Bodong Yang1, Qing Zhao1, Di Wang2
1School of Biotechnology, Key Lab of Industrial Fermentation Microbiology of the Ministry of Education, State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin, 300457, China.
Abstract:
Conventional inductively coupled plasma mass spectrometry (ICP-MS) merely measures total phosphorus within nucleic acid matrices and cannot resolve intact target DNA from degraded oligonucleotide fragments or matrix-originated phosphorus contaminants. In this work, we report a hyphenated size-exclusion chromatography-ICP-MS (SEC-ICP-MS) workflow for direct mass quantification of double-stranded DNA fragments spanning hundreds to thousands of base pairs. Purified DNA fragments are introduced directly via HPLC injection for size-based separation. 31P16O signals and 115In signals are simultaneously monitored by ICP-MS, with indium serving as the internal standard. External calibration using certified inorganic phosphorus solution enables phosphorus quantification, and DNA mass concentrations are subsequently derived from the fixed stoichiometric phosphorus fraction of each defined DNA sequence. The instrumental limit of detection for phosphorus reaches 28 ppb, corresponding to an absolute mass limit of 112 pg. Method trueness was validated with two independent nucleic acid certified reference materials, with relative deviations falling between 1.2 and 5.0%, verifying favorable quantitative accuracy. The workflow was applied to two synthetic DNA fragments (300 bp and 2000 bp), giving average mass concentrations of 141.8 ± 3.7 mg·kg⁻1 and 110.5 ± 3.1 mg·kg⁻1, respectively. Orthogonal cross-validation via the digital polymerase chain reaction (dPCR) produced consistent measurements of 140.5 ± 5.1 mg·kg⁻1 (300 bp) and 113.3 ± 4.3 mg·kg⁻1 (2000 bp), jointly corroborating the robust reliability of this fragment-resolved SEC-ICP-MS quantification strategy. The developed SEC-ICP-MS workflow delivers robust, fragment-resolved absolute quantification for short-to-long DNA constructs and exhibits compatibility with functionalized modified nucleic acids.
Related Concept Videos
Sanger Sequencing
Next-generation Sequencing
Next-Generation Sequencing Methods
Although all next-generation methods use different technologies, they all share a set of standard features.
Maxam-Gilbert Sequencing
Challenges of the Maxam-Gilbert Method
The...
RNA-seq
Before the discovery of RNA-seq, microarray-based methods and Sanger sequencing were used for transcriptome analysis. However, while microarray-based...