Related Experiment Video
Updated: Aug 7, 2026

Procurement for a Vascularized and Reinnervated Abdominal Wall Allotransplantation
Published on: July 18, 2025
Minimally invasive abdominal wall reconstruction with robotic-assisted transversus abdominis release following
Joe Banton1, Jeffrey A Blatnik1, Robert MacGregor1
1Section of Minimally Invasive Surgery, Department of Surgery, Washington University School of Medicine, 660 S Euclid Ave, Box 8109, St. Louis, MO, USA.
Introduction:
Incisional hernias following liver transplantation are common, particularly with bi-subcostal (Mercedes) incisions. Durable repair options and perioperative outcomes in this immunosuppressed population remain poorly defined. We analyzed outcomes following minimally invasive abdominal wall reconstruction (AWR) utilizing robotic-assisted transversus abdominis release (rTAR).
Methods:
Single-center, retrospective review of a prospectively maintained series of post-liver transplant patients referred for incisional hernia repair. Adult patients undergoing elective AWR via robotic TAR between January 2018 and July 2025 were included.
Results:
51 patients underwent elective hernia repair. Mean age was 61, mean BMI at repair was 29.7 kg/m2, and 65% were male. Mean time from transplant to repair was 20.8 months (range 7-64.9 mo). At time of repair, 27.5% were on single-agent, 58.8% on dual-agent, and 13.7% on triple-agent immunosuppression. Median hernia defect size was 144 cm2 (24-507 cm2) and median mesh size was 832 cm2 (390-1512 cm2). Mean operative time was 363 min and average length of stay was 3.8 days (2-9 days). Surgical site occurrences occurred in 4 patients (7.8%), including 2 surgical site infections. No reoperations were required. No hernia recurrences were identified at a median follow-up of 13.4 months.
Conclusions:
Robotic-assisted AWR with rTAR provides a durable and safe approach for complex post-transplant incisional hernias. Minimally invasive component separation limits wound morbidity in the setting of immunosuppression while enabling broad sublay mesh coverage. Further long-term follow-up is ongoing.