Decoupling the dosimetric impact of setup errors and anatomical deformations in image-guided radiotherapy using
Lianzi Zhao1,2,3,4, Ying Guo1,2,3,4, Yuanshuai Di1,2,3,4
1Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai 200032, People's Republic of China.
None:
Objective.Traditional radiotherapy dosimetric analyses are often limited by cone-beam CT artifacts and correlated longitudinal data mismanagement. This study uses artifact-free fan-beam CT (FBCT) and a generalized linear mixed Lasso (glmmLasso) model to decouple interfraction setup errors and anatomical deformations within a simulated image-guided radiotherapy workflow, providing quantitative support for future site-specific ART research.Approach.We retrospectively analyzed 84 patients (head and neck [H&N], thorax, pelvis; n = 28 each). Weekly diagnostic-quality FBCTs served as ground truth. To isolate error sources, we recalculated 1 260 dose distributions under three scenarios: isolated setup errors, isolated deformations, and combined effects. A glmmLasso model, using patient-specific random intercepts andL1penalization, identified the primary geometric drivers of dosimetric variation.Main Results.H&N exhibited minimal setup deviations (< 2.0 mm); dosimetric variance was driven by inter-patient baseline heterogeneity (ICC > 0.73) rather than interfraction deformations. Thoracic setup uncertainties (mean≈4.0 mm) reduced minimum target dose up to 50% for displacements ⩾ 5 mm, but overall variance was primarily governed by non-rigid deformations (marginalR2= 0.423). Pelvic anatomy demonstrated pronounced variability due to bladder filling (DSC: 0.2-0.9), and the coupled scenario further amplified relative deviations in bladder and femoral-head dose metrics.Significance.Utilizing FBCT and high-dimensional feature selection, we decoupled site-specific drivers of dosimetric variation. Quantifying these coupled effects establishes a robust, validated foundation for tailored potential factors to inform ART decision-making.