Subject-independent gait activity recognition using DSAF: dual-stream IMU-EMG attention fusion with asymmetric temporal encoding and physiological complementarity weighting
Zhangyue Xu1, Yan Zhu2, Shurui Li2
1School of Mechanical and Power Engineering, East China University of Science and Technology, Shanghai, China.
Introduction:
Accurate gait recognition using wearable sensors is of significant clinical value for adaptive prosthetic control, lower-limb exoskeleton assistance, and objective rehabilitation assessment. However, subject-independent recognition remains a major challenge, as unseen individuals can exhibit highly variable limb kinematics and muscle activation patterns, and existing approaches often rely on a single sensor modality or naive fusion strategies that fail to leverage the complementary information between inertial and electromyographic signals.
Methods:
To address these gaps, this study proposes DSAF, a dual-stream attention fusion network that separately encodes kinematic (IMU) and neuromuscular (EMG) information, and adaptively integrates them through a physiological complementarity weighting mechanism designed for window-level modality adaptation. The framework is evaluated on the public HuGaDB dataset for eight common locomotion activities (e.g., walking, running, stair negotiation, and sit-to-stand transitions), using a leave-one-subject-out protocol to rigorously assess generalization to new users.
Results:
DSAF achieves 96.41% accuracy, 96.08% macro-precision, 95.62% macro-recall, and 95.81% macro-F1, consistently outperforming recent sequence-learning baselines across all 18 held-out subjects. Ablation studies further confirm that both the modality-specific encoding and the adaptive fusion mechanism contribute positively to the performance.
Discussion:
These findings indicate that adaptive IMU-EMG fusion can effectively strengthen wearable gait recognition, providing a promising solution for real-world rehabilitation monitoring and assistive human-machine interfaces.