Related Experiment Video
Updated: Aug 10, 2026

10:41
Analysis of Cerebral Vasospasm in a Murine Model of Subarachnoid Hemorrhage with High Frequency Transcranial Duplex Ultrasound
Published on: June 3, 2021
Correction to "Transcranial Doppler Ultrasound Velocity Measurements in Children With Sickle Cell Disease in Kenya"
Ejhaem
|August 8, 2026
Insights
This study corrects a previously published article DOI. The correction ensures accurate citation and referencing for future research in the field.
Area of Science:
- Hematology
- Medical Research
Background:
- A previous publication requires correction to ensure scientific accuracy.
- Accurate referencing is crucial for the integrity of scientific literature.
Purpose of the Study:
- To provide a correction for a specific article DOI.
- To maintain the accuracy and reliability of published scientific data.
Main Methods:
- The correction involves updating the article's Digital Object Identifier (DOI).
- This process ensures proper linkage to the intended research article.
Main Results:
- The article DOI has been corrected to 10.1002/jha2.70312.
- This ensures that readers and indexing services can locate the correct publication.
Conclusions:
- The correction maintains the scientific record's integrity.
- Accurate DOIs are essential for reproducible and verifiable research.
Abstract:
[This corrects the article DOI: 10.1002/jha2.70312.].
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
