Related Experiment Video
Updated: Aug 10, 2026

05:53
Candidate Gene Testing in Clinical Cohort Studies with Multiplexed Genotyping and Mass Spectrometry
Published on: June 21, 2018
Detection of Allergy-Related TPSAB1 Copy Number Variation by MALDI-TOF Nucleic Acid Mass Spectrometry
Clinical Laboratory
|August 8, 2026
Summary
A new Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS) method accurately detects copy number variations in TPSAB1 and TPSB2 genes, crucial for allergic diseases. This cost-effective tool shows high reliability for clinical genetic analysis.
Area of Science:
- Genetics
- Molecular Biology
- Diagnostic Assays
Background:
- Genetic variations in TPSAB1 and TPSB2 are associated with allergic diseases.
- Accurate copy number detection of these genes is essential for understanding disease mechanisms.
Purpose of the Study:
- To develop a novel Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS) method.
- To enable simultaneous copy number detection of TPSAB1 and TPSB2 genes.
Main Methods:
- A multiplex PCR-tandem MALDI-TOF MS assay was established.
- Method validation involved 35 standard samples analyzed by droplet digital PCR (ddPCR).
- The assay was applied to 274 population samples for clinical evaluation.
Main Results:
- The MALDI-TOF MS assay achieved 100% accuracy in standard samples.
- Detection limit was 20 ng, with good repeatability and stability.
- A TPSAB1 copy number gain carrier rate of 12.41% was observed in the population cohort.
Conclusions:
- The developed MALDI-TOF MS method is robust, cost-effective, and high-throughput.
- It is suitable for differentiating highly homologous TPS genes.
- This assay shows promise as a reliable clinical tool for TPSAB1 and TPSB2 copy number analysis.
Related Concept Videos
MALDI-TOF Mass Spectrometry
Mass spectrometry is a powerful characterization technique that can identify and separate a wide variety of compounds ranging from chemical to biological entities, based on their mass-to-charge ratio (m/z). The instruments that allow this detection, known as mass spectrometers, have three components: an ion source, a mass analyzer, and a detector. These spectrometers differ based on the nature of their ion source and analyzers.Matrix-assisted laser desorption ionization (MALDI) is a commonly...
Comparing Copy Number Variations and SNPs
Sequencing of the human genome has opened up several best-kept secrets of the genome. Scientists have identified thousands of genome variations that exist within a population. These variations can be a single nucleotide or a larger chromosomal variation.
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...

