Related Experiment Video
Updated: Aug 13, 2026

Rapid and Specific Detection of Acinetobacter baumannii Infections Using a Recombinase Polymerase Amplification/Cas12a-based System
Published on: April 25, 2025
Rapid intrapartum PCR assay for group B streptococcus within a dutch risk-based strategy: diagnostic accuracy and
M A M Bröcking1, M J Nahuis2, W Rozemeijer3
1Northwest Clinics, Department of Obstetrics and Gynecology, Wilhelminalaan 12, 1815 JD Alkmaar, the Netherlands; Amsterdam UMC, Department of Obstetrics, Meibergdreef 9, 1105 AZ, Amsterdam, the Netherlands; Amsterdam Reproduction and Development Institute, Amsterdam, the Netherlands.
Objective:
To compare the diagnostic accuracy of a rapid intrapartum polymerase chain reaction (PCR) assay with standard intrapartum culture for detecting maternal group B streptococcus (GBS) carriage, and to explore potential effects on intrapartum antibiotic prophylaxis (IAP) within a Dutch risk-based strategy.
Background:
GBS is a leading cause of early-onset neonatal sepsis. While many countries apply universal screening, the Netherlands follows a selective, risk-based prevention protocol with markedly lower use of IAP. Standard culture requires 24-48 h, limiting its value in urgent obstetric settings. Rapid intrapartum PCR testing offers results within 1 h and may improve timely decision-making.
Design:
Retrospective diagnostic-accuracy cohort.
Setting:
Secondary care teaching hospital in the Netherlands.
Population:
Women who underwent both intrapartum PCR (Xpert Xpress GBS) and culture between 1 February and 30 September 2024 were identified retrospectively through electronic medical and microbiology records. Testing was performed in women with predefined clinical risk factors according to the local Dutch risk-based protocol. The same rectovaginal swab specimen was used for both rapid PCR analysis and standard culture testing.
Methods:
Diagnostic accuracy of a rapid intrapartum PCR assay was calculated using culture as the reference standard, and expressed primarily as sensitivity and specificity with 95% confidence intervals (CI). PCR and culture results were processed through separate laboratory workflows. Exploratory analyses evaluated IAP administration and test performance across clinical risk factor groups.
Findings:
A total of 177 women were analysed. The PCR assay showed sensitivity of 94.1% (95% CI 80.3-99.3) and specificity of 99.3% (95% CI 96.2-100.0). Of 33 PCR-positive women, 28 (85%) received IAP; non-treatment was due to rapid labour progression or informed refusal. Exploratory subgroup analyses demonstrated similar findings across prolonged rupture of membranes, preterm birth and other clinical risk factor groups.
Interpretation:
Rapid intrapartum PCR testing demonstrated high diagnostic accuracy for GBS detection within a Dutch risk-based prevention protocol. Its integration may support more targeted use of IAP. Prospective multicentre trials are needed to establish clinical impact, cost-effectiveness and neonatal outcomes.
Related Concept Videos
Automated Microbial Diagnostics
Rapid Identification of Pathogens
Real Time RT-PCR
The real-time quantification of the number of amplified products is...