Related Experiment Video
Updated: Aug 13, 2026

Utilizing High Resolution Ultrasound to Monitor Tumor Onset and Growth in Genetically Engineered Pancreatic Cancer Models
Published on: April 7, 2018
Ultrasonic markers for screening intra-abdominal hypertension in patients with pancreatic diseases
Bao-Quan Chen1,2, Xiao-Yi Yan1, Wan-Ying Jia1
1Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China.
Background:
Accurately assessing intra-abdominal hypertension (IAH) is of significant clinical importance in laparoscopic pancreaticoduodenectomy (LPD) and severe acute pancreatitis (SAP), which is closely linked to complications and mortality. This study aimed to identify potential ultrasonic markers for screening IAH in patients who underwent LPD for pancreatic cancer and those with SAP.
Methods:
We conducted a retrospective analysis of 27 patients who were diagnosed with pancreatic cancer and underwent LPD, and 19 patients with SAP admitted to the intensive care unit (ICU) from February 2022 to August 2022. Baseline demographic, ultrasonic markers, and clinical records were obtained and analyzed to identify potential ultrasonic markers for screening IAH. The diagnostic performance was assessed using the area under the receiver operating characteristic (ROC) curve (AUROC).
Results:
Comparative analysis between the two groups showed that in both the LPD and SAP groups, patients with IAH exhibited significantly lower right diaphragm thickening rate (RDTR) and significantly higher right renal interlobar arterial resistive index (RIRI) than those without IAH (all P<0.05). Univariate analysis and multivariate regression analysis showed that the RIRI and RDTR were independent predictors of IAH in the LPD group (P=0.004 and P=0.025, respectively); and the combination of RIRI and RDTR showed promising diagnostic performance for IAH, with an AUROC of 0.894, sensitivity of 93.33%, and specificity of 91.67%. Meanwhile, for the SAP group, only the RDTR served as the marker for screening IAH with an AUROC of 0.872, a sensitivity of 86.67%, and a specificity of 83.33%.
Conclusions:
This preliminary study suggests that clinicians should remain alert to the occurrence of IAH when abnormal ultrasonic markers are screened. Regular intra-abdominal pressure monitoring is recommended in such cases. However, these findings require validation in larger prospective cohorts.
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Assessment of the Abdomen I: Inspection and Auscultation
The abdominal examination is a cornerstone of clinical medicine, serving as a critical tool in diagnosing various gastrointestinal (GI) diseases. It involves a systematic approach that includes inspection and auscultation, each with distinct yet complementary roles in assessing the abdomen. This article will delve into these two primary methods healthcare professionals use to examine the abdomen.
Inspection of the Abdomen
The first step in any abdominal examination is inspection.
Imaging Studies II: Ultrasonography
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Nursing Assessment of the Genitourinary System III: Percussion and Auscultation
Assessment of the Abdomen II: Percussion
Percussion
Percussion is an essential...
