Related Experiment Video
Updated: Aug 13, 2026

A Random-displacement Measurement by Combining a Magnetic Scale and Two Fiber Bragg Gratings
Published on: September 30, 2019
Quasi-Distributed Partial Discharge Monitoring System with Remote Demodulation Based on DFB-FL/Interferometer Hybrid
Yuelan Lu1, Qibing Shao2, Qun Yu3
1School of Low-Altitude Technology and Electronic Information, Guangdong University of Science and Technology, Dongguan 523668, China.
Abstract:
In the field of long-distance partial discharge (PD) detection for submarine cables, there is an urgent need for a remote demodulation distributed detection technology deployable at multiple critical locations to overcome the limitations of single-point measurement. Factory joints of high-voltage submarine cables are high-risk components for PD, and long-distance fiber optic acoustic sensing technology holds the greatest potential for online monitoring. However, due to the viscoelasticity of the joint's polymer insulation structure, sound propagation distance is severely limited, and non-multi-point measurement cannot achieve effective coverage of the measurement area. This paper proposes a quasi-distributed remote demodulation sensing system, in which both the fiber optic interferometer and the distributed feedback fiber laser (DFB-FL) serve as sensors, enabling highly sensitive quasi-distributed PD detection. The DFB-FL itself is highly sensitive to strain, and the multiple fiber coils formed by the interferometer arms are also highly sensitive to strain. Both can be modulated by the micro-strain induced by the acoustic field generated from PD in the polymer solid, producing phase shifts of the optical waves, which are then intrinsically demodulated by the interferometer system to extract the vibration signals caused by the discharge. Theoretical analysis shows that the sensitivity increases with the length of the unbalanced arm, with the upper limit constrained by laser coherence and optical attenuation; for the PD frequency band, the optimal unbalanced length is below 200 m-this design rule is applicable to on-chip interferometric sensors. The interferometer coils employ bend-insensitive fibers to suppress optical loss and improve fringe visibility. Meanwhile, three fiber coil configuration schemes are constructed to enhance the detection sensitivity to acoustic signals. Simulation results generate frequency response contour maps based on Young's modulus, indicating that the solid-wound coil achieves the highest amplitude and the broadest bandwidth, with an optimal response frequency of approximately 50 kHz. Experimental results demonstrate that among the three structure types, the solid-wound coil also achieves the largest response ratio. Finally, in tests performed on a 220 kV submarine cable intermediate joint (with the system installed inside the metallic sheath), the minimum detectable discharge level in the DFB-FL region reached 6.75 pC, while that for the fiber coil reached 12.66 pC; when installed outside the metallic sheath, the minimum detectable discharge levels were 53.2 pC for the grating region and 89.6 pC for the fiber coil.
