Using Detection Efficiency as an Indicator of Losses During Atom Probe Tomography Analysis of Oxygen-Rich Materials
Tom Veret1, Celia Castro1, Auriane Etienne1
1CNRS, INSA Rouen Normandie, Groupe de Physique des Matériaux, UMR 6634, Univ Rouen Normandie, Rouen F-76000, Avenue de l'Université, 76800 Saint-Étienne-du-Rouvray, France.
Abstract:
Atom probe tomography (APT) enables atomic-scale compositional analysis in a wide range of materials; however, quantification in oxygen-rich materials remains challenging due to apparent oxygen losses during analysis. We present here a correlative method, combining transmission electron microscopy and analytical or numerical modeling, to estimate the APT analyzed volume and detection efficiency. Applied to CePO4 samples, the approach revealed that increasing laser pulse energy reduces detection efficiency, likely through enhanced neutral desorption. Analysis on pure aluminum confirmed the robustness of the method, while highlighting limitations in accurately determining the evaporated depth and compositional uncertainties. The results demonstrate consistent qualitative trends with known oxygen loss mechanisms in synthetic monazites. This work provides a foundation for developing a method to better understand the loss of neutral species during field evaporation and consequently the compositional biases observed in APT analyses. By linking morphological measurements with modeling of the analyzed volume, it opens the way to a more accurate interpretation of detection efficiency variations and elemental deficiencies in oxygen-rich materials.
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Atomic Emission Spectroscopy: Lab
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...