Ultrafast Time-resolved Near-IR Stimulated Raman Measurements of Functional π-conjugate Systems
Published on: February 10, 2020
Improved precision of Raman-derived 13C/12C and 18O/16O in CO2 using bandwidth-fluctuation correction and optimized
Abstract:
By exploiting isotopologue-specific Raman bands, Raman spectroscopic mass spectrometry has emerged as a promising technique for ascertaining the carbon and oxygen isotopic ratios of micrometer-scale CO2 fluids. For this study, we improve the analytical precision of this technique by reanalyzing Raman spectra of CO2 at 10 MPa obtained using a high pixel-resolution spectroscopic configuration [Appl. Opt.64, 2711 (2025)APOPAI0003-693510.1364/AO.557083]. Two curve-fitting procedures were applied to the spectral data. In addition, bandwidth-fluctuation correction was introduced to compensate for instrumental drift affecting fitted peak ratios, based on correlation between fitted peak ratios and variations in Raman bandwidths. Combined application of optimized curve-fitting procedures and bandwidth-fluctuation correction improves the precision of Raman-derived isotopic ratios considerably. Results show that the present method enables determination of 13C/12C and 18O/16O of 10 MPa CO2 fluid, with respective precisions of approximately 2-3‰ and 9-12‰.
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
NMR Spectrometers: Resolution and Error Correction
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to the...