Related Experiment Video
Updated: Aug 15, 2026

Microfabrication of Implantable Optics Integrated in a Microstructured Imaging Window for Advanced In Vivo Imaging
Published on: April 11, 2025
Profile control of fibre-based micro-mirrors using adaptive laser shooting with in situ imaging: erratum
Abstract:
An erratum of [Opt. Express33, 39009 (2025)10.1364/OE.564341]: the measured cavity finesses were overestimated by a factor of two, due to a programming error in a fitting function used in the cavity finesse analysis, which led to an underestimation of the cavity loss by a factor of two. The newly confirmed cavity loss deviates from our previous estimation. We performed additional measurements and confirmed that the mirror coating losses are higher than previously expected. Nonetheless, we observe no additional loss attributed to our machining method, e.g., through surface roughness or profile deviation. Thus, our main results and conclusions in the paper are unaffected.