Related Experiment Video
Updated: Aug 15, 2026

08:53
Quantitative and Qualitative Method for Sphingomyelin by LC-MS Using Two Stable Isotopically Labeled Sphingomyelin Species
Published on: May 7, 2018
A Rapid and Sensitive LC-MS/MS Method for Quantification of NDSRI in Melatonin Drug Product via Controlled In Situ
Jaya Yalamanchili1, Ganja Himavathi1, Salakolusu Suresh2
1Department of Chemistry, GITAM School of Science, GITAM Deemed to be University, Visakhapatnam, Andhra Pradesh, India.
Biomedical Chromatography : BMC
|August 14, 2026
Summary
Nitrosamine impurities in drugs are a safety risk. A validated LC-MS/MS method using a scavenger prevents their formation during analysis, ensuring accurate quantification of N-Nitroso melatonin.
Area of Science:
- Pharmaceutical Analysis
- Analytical Chemistry
- Drug Safety
Background:
- Nitrosamine drug substance-related impurities (NDSRIs) present mutagenic and carcinogenic risks, necessitating stringent regulatory control (ICH M7).
- Reactive amines in active pharmaceutical ingredients can lead to in situ NDSRI formation during analysis, compromising data accuracy.
- Melatonin, with its reactive amine group, serves as a model to address these analytical challenges.
Purpose of the Study:
- To develop and validate a precise LC-MS/MS method for quantifying N-Nitroso melatonin.
- To mitigate in situ NDSRI formation during sample preparation using a scavenger.
- To ensure the reliability and regulatory compliance of analytical methods for NDSRI monitoring.
Main Methods:
- Development of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method.
- Incorporation of a scavenger during sample preparation to inhibit in situ nitrosamine formation.
- Validation of the method according to regulatory standards, including specificity, linearity, accuracy, precision, sensitivity, and robustness.
Main Results:
- The LC-MS/MS method demonstrated excellent linearity (R² = 0.9983) and sensitivity (LOD: 0.9 ng/mL, LOQ: 1.8 ng/mL).
- Accuracy (85.3%–95.9% recovery) and precision (%RSD < 2%) were within acceptable limits.
- The scavenger effectively prevented false positives by suppressing in situ nitrosamine formation, confirming method specificity and data integrity.
Conclusions:
- A validated LC-MS/MS method with a scavenger effectively quantifies N-Nitroso melatonin, preventing analytical artifacts.
- This approach ensures data integrity and supports regulatory compliance for NDSRI monitoring in pharmaceuticals.
- The validated methodology offers a transferable framework for analyzing other drug products containing reactive amines.