A Novel Method to Determine the Longitudinal Antibacterial Activity of Drug-Eluting Materials
Published on: March 3, 2023
Measuring vancomycin using paired pulse voltammetry with a wireless instantaneous neurotransmitter concentration
Sheng-Ta Tsai1,2,3,4, Mohamed M El-Gohary1, Maximiliano A Hawkes1,5,6
1Neural Engineering and Precision Surgery Laboratories, Mayo Clinic, 200 First Street SW, Rochester, MN USA.
Abstract:
Vancomycin is a glycopeptide antibiotic widely used for severe Gram-positive infections, particularly methicillin-resistant Staphylococcus aureus (MRSA). However, its narrow therapeutic index necessitates precise monitoring to avoid nephrotoxicity, ototoxicity, or hematologic toxicity. Current therapeutic drug monitoring relies on serum assays requiring several hours, delaying timely dose adjustments. Electrochemical approaches such as fast-scan cyclic voltammetry (FSCV) offer potential for real-time bedside monitoring. We used bare AS4 carbon fiber microelectrodes (CFMs) as the vancomycin sensor. The Wireless Instantaneous Neurotransmitter Concentration Sensing (WINCS) Harmoni system, a portable and clinically compatible platform, was used to perform FSCV measurements of vancomycin. Waveform parameters were optimized, and paired-pulse voltammetry (PPV) was applied to enhance detection selectivity in vitro across varying vancomycin concentrations. Two distinct oxidation peaks of vancomycin were observed. PPV analysis indicated that the + 1.44 V peak is predominantly pH-independent, while the + 0.69 V peak demonstrates pH-dependent characteristics. Furthermore, the optimized FSCV waveform yielded a detection limit of 0.36 μM with stable and reproducible signal performance. Paired-pulse FSCV using the WINCS Harmoni platform enables sensitive, real-time electrochemical detection of vancomycin. This approach may support future rapid point-of care monitoring and inform individualized dosing strategies in critical care settings.
More Related Videos
Related Concept Videos
Voltammetric Techniques: Pulse Voltammetry
Automated Microbial Diagnostics
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Controlled-Current Coulometry: Overview
Voltammetric Techniques: Linear-Scan (E vs Time)
Controlled-Current Coulometry: Coulometric Titration
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...