Related Experiment Video
Updated: Aug 18, 2026

Surface Mapping of Earth-like Exoplanets using Single Point Light Curves
Published on: May 10, 2020
Wavelength Requirements for Life Detection via Reflected Light Spectroscopy of Rocky Exoplanets
Joshua Krissansen-Totton1,2,3, Anna Grace Ulses1,2,3, Maxwell K Frissell1,4
1Department of Earth and Space Sciences, University of Washington, Seattle, Washington, USA.
None:
Searching for signs of life is a primary goal of the Habitable Worlds Observatory (HWO). However, merely detecting oxygen, methane, or other widely discussed biosignatures is insufficient evidence for a biosphere. In parallel with biosignature detection, exoplanet life detection additionally requires characterization of the broader physicochemical context to evaluate planetary habitability and the plausibility that life could produce a particular biosignature in a given environment. Life detection further requires that we can confidently rule out photochemical or geological phenomena that can mimic life (i.e., "false positives"). Evaluating false-positive scenarios may require different observatory specifications than biosignature detection surveys. Here, we explore the coronagraph requirements for assessing habitability and for cautiously excluding known false-positive (and false-negative) scenarios for oxygen and methane, the two most widely discussed biosignatures for Earth-like exoplanets. We find that broad wavelength coverage ranging from the near ultraviolet (UV; 0.26 µm) and extending into the near infrared (NIR; 1.7 µm) is necessary to contextualize these potential biosignatures with HWO. The short-wavelength cutoff is driven by the need to identify Proterozoic-like biospheres via O3, whereas the long-wavelength cutoff is driven by the need to contextualize O2 and CH4 biosignatures via constraints on carbon-bearing atmospheric species. The ability to obtain spectra with signal-to-noise ratios of 20-40 across this 0.26-1.7 µm range (assuming R = 7 UV, R = 140 VIS, and R = 70 NIR) is also required. While not every Earth-analog biosignature and false positive can be unambiguously identified with these capabilities-and the plausibility and contextual clues of many biosignature false positives remain an area of active research-our minimal spectral recommendations would enable a broad search for Earth-like life assuming such observations are achievable for a statistically meaningful number of HWO targets.
Related Concept Videos
UV–Vis Spectrometers
Spectrophotometry: Introduction
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Interaction of EM Radiation with Matter: Spectroscopy

