Related Experiment Video
Updated: Aug 21, 2026

Measuring Carbon-based Contaminant Mineralization Using Combined CO2 Flux and Radiocarbon Analyses
Published on: October 21, 2016
Study on radon mitigation performance of building foundations with adsorption layers
Yongjun Ye1, Yabing Zhou2, Haofeng Wang2
1National Joint Engineering Research Center for Airborne Pollutants Control and Radiological Protection in Building Environment, University of South China, Hengyang, Hunan, 421001, China; Key Discipline Laboratory for National Defense for Biotechnology in Uranium Mining and Hydrometallurgy, University of South China, Hengyang, 421001, China; School of Resources Environment and Safety Engineering, University of South China, Hengyang, 421001, China.
None:
Radon, a primary indoor radioactive contaminant, migrates through building foundations and poses radiation hazards to indoor living environments. To mitigate indoor radon pollution, this paper systematically investigates the adsorption-seepage synergistic mechanism of radon mitigation in building foundations by constructing an adsorption layer. This study adopts the Activated Carbon Purification Closed-Loop Method (ACPCM) to measure the radon exhalation rate of the experimental column, and establishes a geometric model of building foundations using Computational Fluid Dynamics (CFD) to evaluate the radon mitigation performance of foundations with adsorption layers under varied parameters and crack scenarios. The results show that as the adsorption coefficient of the adsorption layer rises, the slab radon exhalation-rate declines gradually, while porosity variations show a growing influence on radon exhalation of the slab. On this basis, a calculation model for the radon mitigation rate is established. Comparative analysis indicates that slab radon exhalation decreases as the sump pressure differential increases, with negative pressure outperforming positive pressure; furthermore, the adsorption-seepage synergistic method is superior to the traditional soil depressurization technique. In addition, concrete cracks impair the synergistic radon mitigation performance; wider cracks and those closer to radon sumps result in greater performance attenuation. The research findings provide new insights for the high-efficiency radon prevention and mitigation design of residential and public building foundations.
Related Concept Videos
Adsorption Isotherms II
Waterproofing and Anti-Bacterial Admixtures in Concrete
Waterproofing admixtures render concrete hydrophobic,...
Measurement of Air Content in Concrete
The pressure method,...