Related Experiment Video
Updated: Aug 21, 2026
![Automated Preparation of [68Ga]Ga-3BP-3940 on a Synthesis Module for PET Imaging of the Tumor Microenvironment](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F68356.jpg&w=3840&q=50)
Automated Preparation of [68Ga]Ga-3BP-3940 on a Synthesis Module for PET Imaging of the Tumor Microenvironment
Published on: April 25, 2025
Diagnostic value of [68Ga]Ga-FAPI-46 PET in comparison to [18F]FDG PET in triple-negative breast cancer and potential
Alina Toni Küper1, Ieva Ciuciulkaite2, Anja Welt3,4
1Department of Nuclear Medicine and German Cancer Consortium (DKTK), University Hospital Essen, University of Duisburg-Essen, Hufelandstrasse 55, Essen, 45147, Germany. Alina.Kueper@uk-essen.de.
Abstract:
This single-center subgroup analysis of a prospective trial (NCT04571086) at University Hospital Essen investigated tumor uptake and detection rates of [68Ga]Ga-FAPI-46- versus [18F]FDG PET in triple-negative breast cancer (TNBC) patients undergoing initial or follow-up staging. Lesions were recorded across anatomical regions, with detection efficacy, uptake values, tumor-to-liver ratios, and tumor volumes assessed. 22 patients were included (initial- n = 10, follow-up staging n = 12). No significant difference in region-based detection rates was observed between [18F]FDG- (93%, 53/57 regions) and [68Ga]Ga-FAPI-46 PET (93%, 53/57 regions) (McNemar p = 1.0). Three patients (25%) at follow-up staging showed an average tumor SUVmean ≥5 on [68Ga]Ga-FAPI-46 PET; 2/3 showed SUVmax >10 in most lesions. Mean tumor volume was higher for [68Ga]Ga-FAPI-46, though not statistically significant at initial- (50.1 ± 120.8 mL vs. 11.9 ± 18.5 mL) and follow-up staging (102.2 ± 122.3 mL vs. 79.0 ± 90.4 mL). [⁶⁸Ga]Ga-FAPI-46 PET demonstrated comparable detection in TNBC; high tumor uptake in a subset, supporting its theranostic potential.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
![An Automated Radiosynthesis of [68Ga]Ga-FAPI-46 for Routine Clinical Use](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F66708.jpg&w=3840&q=50)
