Related Experiment Video
Updated: Aug 21, 2026

Remotely Triggered LAD Occlusion Using a Balloon Catheter in Spontaneously Breathing Mice
Published on: March 22, 2024
Case report: successful retrieval of an entrapped balloon during balloon pericardiotomy after rupturing
Justin Ka-Ho Wong1, John Cheong-Hin Chan1, In-Wai Tam1
1Department of Medicine, Pamela Youde Nethersole Eastern Hospital, 3 Lok Man Road, Chai Wan, Hong Kong SAR.
Background:
Balloon rupture and entrapment during percutaneous balloon pericardiotomy (PBP) is rare and usually requires surgical intervention. However, various bailout techniques can be tried. We describe a case of balloon entrapment in the pericardium and the strategies employed to successfully remove the balloon percutaneously.
Case Summary:
A 58-year-old woman presented with recurrent malignant pericardial effusion. She refused surgery and opted for PBP. During the procedure, the balloon ruptured and was trapped within the pericardium. The entrapped balloon was secured by snaring onto the proximal end of the balloon. The distal end of the balloon remained trapped across the pericardium as it did not deflate completely after rupturing. Therefore, a needle was inserted under fluoroscopic guidance to decompress the balloon, which enabled its successful removal percutaneously.
Discussion: