Pediatric ventricular assist device (VAD) use exceeding six months is common, with most children eventually transplanted. However, long-term VAD support presents significant risks and requires further study.
Area of Science:
- Pediatric Cardiology
- Mechanical Circulatory Support
- Pediatric Cardiac Surgery
Background:
- Ventricular assist device (VAD) use in children exceeding six months is frequent, yet outcomes data remain limited.
- Understanding long-term VAD support characteristics and adverse events is crucial for pediatric heart failure management.
Purpose of the Study:
- To characterize pre-implant factors, survival rates, and adverse event frequencies in pediatric patients requiring VAD support for over six months.
- To compare outcomes between children supported by VADs for longer-term (>6 months) versus shorter-term (≤6 months) durations.
Main Methods:
- Analysis of pediatric patients (<19 years) who received VADs between September 2012 and March 2022, utilizing the Pediatric Interagency Registry for Mechanical Circulatory Support (PEDIMACS) database.
- Survival analysis was performed, censoring for transplantation or cessation of support, with competing risk analysis for death, transplant, and recovery.
- Patients alive on VAD support at six months were followed up to 24 months and compared to those supported for ≤6 months.
Main Results:
- Of 1137 pediatric patients, 18.0% required VAD support for >6 months. These patients were older and more frequently had cardiomyopathy and implantable continuous devices.
- At two years post-implant, 65% of longer-term VAD patients were transplanted, 9% died, and 20.3% remained on support.
- Mortality risk factors included prior cancer, dialysis, non-implantable continuous devices, and ascites. Common adverse events were infection (27%), device malfunction/pump thrombosis (13.6%), and stroke (4.9%).
Conclusions:
- While most pediatric VAD patients requiring >6 months of support undergo transplantation, a significant portion remains on VAD support at two years.
- Further research is necessary to investigate the morbidity and quality of life associated with long-term VAD support in children.
Background:
One in 5 children with a ventricular assist device (VAD) remains on the device for >6 months. However, there are sparse outcomes data. We sought to characterize preimplant characteristics, survival, and frequency of adverse events.
Methods:
Patients aged <19 years who underwent VAD placement (September 2012-March 2022) and registered in the Society of Thoracic Surgeons' PEDIMACS (Pediatric Interagency Registry for Mechanical Circulatory Support) database were included. Patients alive on VAD support at 6 months were followed up to 24 months and compared with those supported ≤6 months. Survival analyses censored for transplantation or cessation of support. Competing risk analysis was used for death, transplant, and recovery.
Results:
Of 1137 patients, 205 (18.0%) were supported on the device for >6 months. Compared with those supported ≤6 months, those supported >6 months were older (11.2 [5.0-15.2] versus 4.9 [0.6-13.4] years; P<0.001), and had a higher frequency of cardiomyopathy (67.6% versus 59.6%; P=0.029) and implantable continuous devices (68.3% versus 33.6%; P<0.0001). At 2 years from implant, 65% of patients with longer-term use VADs were transplanted, 9% died, and 20.3% were still alive on the device. Mortality risk factors included prior cancer (hazard ratio [HR], 7.77 [95% CI, 2.04-29.55]), dialysis (HR, 3.96 [95% CI, 1.02-15.35]), nonimplantable continuous device (HR, 4.88 [95% CI, 1.45-16.42]), and ascites (HR, 3.86 [95% CI, 1.21-12.34]). Adverse events included infection (27%), device malfunction or pump thrombosis (13.6%), and stroke (4.9%).
Conclusions:
Amongst patients on VAD >6 months, most undergo transplant; however, 20.3% remain on support at 2 years. Further study of morbidity and quality of life is needed.