Related Experiment Video
Updated: Aug 23, 2026

Acquiring Hyperpolarized 129Xe Magnetic Resonance Images of Lung Ventilation
Published on: November 21, 2023
Artificial count enhancement in lung scintigraphy for acquisition acceleration and pseudo-planar generation
Amir Jabbarpour1, Siraj Ghassel2, Sanaz Kaviani3,4
1Department of Physics, Carleton University, Ottawa, Ontario, Canada.
Abstract:
Objective.Ventilation-perfusion (V/Q) planar scintigraphy remains widely used for diagnosing pulmonary embolism, despite the reported superior diagnostic performance ofV/QSPECT. In part, SPECT adoption is limited by the differences in clinical interpretation. Pseudo-planar from SPECT data can facilitate transition to SPECT, but existing methods, such as summed angular projections or forward reprojection, fail to reliably reproduce true planar image characteristics.Approach.We propose a novel artificial intelligence-based count enhancement framework to generate high-fidelity pseudo-planar perfusion images (pQ) from low-count inputs. Two conditional generative adversarial networks (cGANs) were trained using (i) 10% Poisson-resampled planar perfusion images and (ii) matched single-projection SPECT views as inputs, with corresponding full-count planar perfusion images as ground truth. The models were trained and evaluated on 829 paired planar and SPECT studies from a multi-scanner clinical cohort. Performance was assessed using quantitative image similarity metrics (SSIM, PSNR, MSE) and a clinically meaningful task-based evaluation using a previously validated deep learning computer-assisted diagnostic model for vascular defect detection via free-response receiver operating characteristic analysis.Main Results.The cGAN trained on resampled planar images achieved the highest image fidelity (test SSIM: 0.70 ± 0.05; PSNR: 22.3 ± 1.2 dB), significantly outperforming SPECT-trained models and the conventional summed angular method (p< 0.001). In downstream clinical evaluation, this model also yielded superior defect detection performance (sensitivity: 0.800 ± 0.035 at 1.0 false positives per projection), surpassing current clinical practice of the summed angular method.Significance.This study introduces the first AI-based framework for generating pseudo-planar lung scintigraphy from low-count data. The proposed method demonstrates improved image realism and clinically relevant defect preservation, supporting its potential for hybrid planar-SPECT workflows inV/Qimaging and for accelerating acquisition of planar images.
More Related Videos
05:07Pulmonary Structural MRI using Free-Breathing, Self-Gated Ultra-short Echo Time Imaging
Published on: September 6, 2024
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020