Related Experiment Video
Updated: Aug 26, 2026

Conducting Respiratory Oscillometry in an Outpatient Setting
Published on: April 8, 2022
Assessing pulmonary function in 3-year-old children using respiratory oscillometry: a validation study in rural
Laura M Grajeda1,2, Keyla Castellanos2, Tatiana Petrovick3
1Global Health Institute, Department of Epidemiology and Biostatistics, University of Georgia, Athens, GA, USA.
Background:
Respiratory oscillometry can inform early-life lung function, but evidence supporting its use in Guatemala is limited. We assessed the validity and reliability of respiratory oscillometry in 3-year-old Guatemalan children and whether these improve with quality control (QC).
Methods:
During home visits, we measured respiratory oscillometry resistance (R) and reactance (X) at 7 Hz (R7 and X7), the frequency dependence of resistance (R7-R19) and the area of reactance (AX) in 666 children participating in the Household Air Pollution Intervention Network trial. Standard measurement QC removed artefacts using commercial software and selected the first three measurements with an R7 coefficient of variation of ≤15%. Alternative investigators' methods varied in QC procedures. We evaluated validity as the proportion of variability in tests predicted by a child's height (R2) and, in a subset of 50 children, as agreement with test results after manual QC by a paediatric pulmonologist. Reliability was assessed by the intraclass correlation coefficient (ICC) of repeated tests.
Results:
We collected oscillometry results from 537 children. Height explained 5-15% of the variability in R7, X7 and AX, but none in R7-R19. The correlation between standard and manually cleaned tests ranged from 0.66 to 0.97, depending on the parameter. Of the first tests, between-day ICCs using the standard method for R7, R7-R19, X7 and AX were 0.68, 0.45, 0.60 and 0.71, respectively, and the best between-day ICCs using an alternative method were 0.75, 0.57, 0.69 and 0.74, respectively.
Discussion:
We demonstrated good validity and reliability of respiratory oscillometry measurements collected at home from preschool-aged Guatemalan children. Investigators' automated QC methodology performed equally to or better than standard methodology.
Related Concept Videos
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like asthma or COPD,...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Respiratory Volumes and Capacities I