Related Experiment Video
Updated: Aug 28, 2026

Quantitative Visualization and Detection of Skin Cancer Using Dynamic Thermal Imaging
Published on: May 5, 2011
See the (In)Visible: Infrared Thermography for Characterizing Thermal Patterns Associated with Peripheral Arterial
Slobodan Tanasković1,2, Aleksandra Milačić1, Nikola Ružić3
1Institute for Cardiovascular Diseases "Dedinje", 11040 Belgrade, Serbia.
Abstract:
Background/Objectives: Peripheral arterial disease (PAD) and diabetes mellitus (DM) may produce different and overlapping plantar thermal patterns. This study descriptively characterized whole-foot temperature-distribution patterns in clinically defined healthy, PAD, DM, and combined PAD_DM cohorts. Methods: This single-center, exploratory, cross-sectional observational study included 73 participants: healthy controls (n = 21), isolated PAD (n = 13), isolated DM (n = 19), and combined PAD_DM (n = 20). Right- and left-foot temperature distributions were processed separately for each participant and interpreted as one paired bilateral thermal footprint using patient-level histograms, representative bilateral kernel density estimation (KDE) profiles, and a cohort-derived deterministic rule-based model. The model was developed from the present cohort and was not evaluated as an independent diagnostic classifier. Results: Among healthy controls, 11 of 21 participants (52.4%) were assigned to healthy and 8 of 21 (38.1%) to borderline healthy categories. In the DM cohort, 7 of 19 participants (36.8%) were assigned to DM, 3 of 19 (15.8%) to borderline healthy/suspected DM or controlled DM, 3 of 19 (15.8%) to DM suspected PAD, and 5 of 19 (26.3%) to PAD_DM. In the combined PAD_DM cohort, 15 of 20 participants (75.0%) were assigned to PAD_DM. The isolated PAD cohort was the most heterogeneous: 6 of 13 participants (46.2%) were assigned to PAD_DM, while none were assigned to the isolated PAD output. Conclusions: This exploratory, cross-sectional study demonstrated that whole-foot plantar temperature distributions can descriptively characterize differences among healthy individuals, patients with isolated DM, and those with combined PAD and DM. While healthy controls generally demonstrated symmetric thermal footprints, the DM cohort frequently exhibited globally elevated and compact temperature-distribution profiles, while mixed asymmetric patterns were common in participants with combined PAD and DM. In contrast, the isolated PAD cohort was characterized by pronounced thermal heterogeneity.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Peripheral Artery Disease I: Introduction

