Tensile Response and Energy Absorption of Galvanized Steel Mesh-Reinforced Cement Mortar with Alkali-Resistant Glass
Leonardo Rodríguez1, Rodrigo Valle1, César Garrido2
1Construction Multidisciplinary Research Group, Facultad de Arquitectura, Construcción y Medio Ambiente, Universidad Autónoma de Chile, Talca 3460000, Chile.
Abstract:
This study investigates the direct tensile mechanical behavior of cement mortar plates reinforced with a galvanized steel mesh and randomly incorporated alkali-resistant glass fibers. An experimental program was executed using direct tensile tests on thin mortar specimens containing fiber volumetric fractions of 0%, 4%, 6%, 8%, and 10% relative to the cement volume. To rigorously characterize the mechanical response, the study quantified the apparent initial stiffness, 0.2% offset stress, ultimate tensile strength, and post-offset energy absorption capacity. Results indicate that increasing alkali-resistant glass-fiber content systematically modified the global tensile response of the composite system. At 10% glass-fiber content, the mean crosshead-derived apparent initial tensile stiffness was 10.43 times that of the reference group without glass fibers. The characteristic stress determined using the adopted 0.2% offset criterion and the ultimate tensile strength increased by 154.5% and 74.1%, respectively, while the apparent post-offset energy absorption increased by 68.4%. Because strain was derived from crosshead displacement, the apparent stiffness and energy-absorption parameters represent the global specimen-grip-machine response rather than intrinsic material properties. The experimental results exhibited acceptable repeatability, although the apparent tensile stiffness showed greater variability than the strength-related parameters. These findings support the continued development of the investigated composite configuration for thin cementitious elements requiring improved tensile response and damage tolerance.
More Related Videos
Related Concept Videos
Ferrocement
Fiber Reinforced Concrete
Alkali Aggregate Reaction in Concrete
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in ASTM C...
Reinforced Brick Masonry
To fortify brick walls...
Reinforcements in Concrete