Related Experiment Video
Updated: Aug 28, 2026

Automated Deployment of an Internet Protocol Telephony Service on Unmanned Aerial Vehicles Using Network Functions Virtualization
Published on: November 26, 2019
Vision-Assisted UAV Relay Triggering for Proactive Blockage Mitigation in Air-Ground Integrated mmWave V2X Networks
Yicheng Wang1, Weiyan Chen2, Luting Kong2
1School of Information and Communication Engineering, Beijing University of Posts and Telecommunications, Beijing 100876, China.
Abstract:
Millimeter-wave (mmWave) vehicular-to-everything (V2X) links are highly vulnerable to sudden blockages in dense urban traffic. Since terrestrial roadside links can degrade rapidly, and alternative ground paths are often limited, maintaining reliable service with only ground networking resources remains challenging. To enhance link reliability by exploiting aerial relay resources in air-ground integrated networks, this paper proposes a vision-assisted unmanned aerial vehicle (UAV) relay triggering framework. The framework uses roadside multi-camera images to predict the future link state of a target vehicle and triggers a UAV decode-and-forward (DF) relay before the direct roadside-unit (RSU)-vehicle link becomes unreliable. To enable target-specific prediction, a template-guided image-matching module is developed to localize the target vehicle in multi-view images. The matched features are fused and temporally modeled to predict future LoS, NLoS, and Absent states, with the predicted NLoS probability further used to determine the UAV activation decision through a probability-based triggering policy. Simulation results on a 3D ray-tracing urban V2X dataset show that the proposed dual-view predictor achieves about 99% validation accuracy, compared with about 87% for the single-view baseline. The proposed relay triggering scheme reduces the outage probability from 15.08% for RSU-only transmission and 4.49% for reactive relaying to 0.76%, and improves the 5th-percentile rate from 11.72 Mbps to 22.49 Mbps over reactive relaying.
Related Concept Videos
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Directional Relays
Pilot and Numeric Relaying
Overcurrent Relays
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
Differential Relays
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...