Continuous-Wave Propagation Channel-Sounding Measurement System - Testing, Verification, and Measurements
Published on: June 25, 2021
A Prototype Distributed Six-Port Reflectometer-Based Transmission-Only Vector Network Analyzer
Muhammad Hashir1, Colin Gilmore1, Joe LoVetri1
1Electrical and Computer Engineering Department, University of Manitoba, Winnipeg, MB R3T 2N2, Canada.
Abstract:
A novel distributed Transmission-Only Vector Network Analyzer (TVNA) based on two Six-Port Reflectometers (SPRs) is experimentally verified. The prototype distributed SPR-TVNA measures S21 and operates with two independent RF sources, allowing the two ports of the Device Under Test (DUT) to be widely separated with no common cables coming to a central location. Using the distributed SPR-TVNA allows for measurements of, e.g., distantly separated antennas, or taking grain bin imaging measurements that would otherwise require long coaxial cables. A key issue of these large DUTs is accurate measurement of the through-measurement, S21. The distribution (separation) of the two RF sources in the SPR-VNA requires novel procedures to obtain accurate results. The results are confirmed using simulations and experiments, with the experimental results obtained using custom-built hardware. While, in theory, a full VNA can measure S11 and S22, which is confirmed through simulation, the experimental results show significant errors in S11 and S22. We thus call the current device a Transmission-Only VNA. The fundamental math of the SPR-VNA means there is a ±180° phase uncertainty that must be solved, e.g., via a wide-band sweep looking for phase jumps. The experimental S21 measurements of the prototype show maximum errors of 1.5 dB in magnitude and 6 degrees in phase over a bandwidth of 0.6-1.2 GHz.
Related Concept Videos
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Bewley Lattice Diagram
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...