Automated CO2 insufflation and image quality in CT colonography
J M Jensen1, D M Toft2, S R Rafaelsen1
1Department of Radiology, University Hospital of Southern Denmark, Vejle Hospital, Denmark; Department of Regional Health Research, University of Southern Denmark, Odense, Denmark.
Introduction:
CT colonography is an established technique for detecting polyps and colorectal cancer, particularly in patients unable to undergo conventional colonoscopy. The aim of this study was to evaluate the volume of automated CO2 insufflation, radiation dose, and diagnostic image quality in patients undergoing CT colonography.
Methods:
This single-centre retrospective study included patients referred for CT colonography following incomplete or contraindicated colonoscopy. Examinations were performed in supine and prone positions. Radiation dose for each position was collected, including CT dose index volume (CTDI) and dose-length product (DLP). Colonic distention was graded from radiology reports by four radiologists using a five-point Likert scale (1 = poor, 5 = excellent); examinations were classified as diagnostic or non-diagnostic. Statistical analysis examined the association between CO2 insufflation volume and image quality.
Results:
A total of 243 CT colonography examinations (188 women, 55 men; median age 71 years) were analysed. The median CO2 insufflation volume was 6 L (range 1.5-16 L). Median total DLP was 594 mGy cm (IQR 438.8-866.1). Overall, 222 examinations (91.4%) were considered diagnostic, while 21 (8.6%) were non-diagnostic. Colonic distention was rated as excellent in 131 cases (53.9%), good in 25 (10.3%), sufficient in 41 (16.9%), suboptimal in 35 (14.4%), and poor in 11 (4.5%).
Conclusion:
A median of 6 L of CO2 was used to achieve diagnostic colonic distention, with a median radiation dose of 594 mGy cm. Most examinations in the study achieved an image quality score of 4 or higher, sufficient for accurate interpretation.
Implications For Practice:
Higher-than-expected CO2 volumes were observed, highlighting the importance of optimizing insufflation protocols to balance image quality, and standardization in clinical practice.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...