Ultrasound swallowing assessment: the impact of image post-processing on measurement reliability
Katharina Winiker1, Sruthy Vijayan2,3, Alan Brook4
1Department of Research and Development, Swiss University of Speech and Language Sciences (hlo), Bahnhofplatz 2, St.Gallen, 9000, Switzerland. katharina.winiker@hlo.ch.
Abstract:
The use of ultrasound for swallowing assessment is promising; yet its application has not translated from research into routine clinical practice. While sufficient reliability is key to support implementation, insufficient reliability for swallowing measures has been documented for pocket-sized ultrasound technology. Image quality, a known prerequisite for reliability, may be compromised in small-sized ultrasound technology. This study explored the impact of ultrasound image post-processing on measurement reliability of swallowing parameters. Ultrasound images (n = 30) of hyoid excursion, thyrohyoid approximation, and submental muscles were selected from a database of images previously collected using a pocket-sized ultrasound system in healthy adults. For this pilot study, images were measured at two time points by four raters with and without experience in ultrasound imaging. For those with experience, their engagement with ultrasound was gained in the context of research data collection, rather than daily clinical practice. At both time points, raters measured each image once with and once without the application of an image processing software that was developed to improve image contrast and image features. ICCs were calculated using linear mixed effects analyses to evaluate inter- and intra-rater measurement reliability. Intra- and inter-rater ICCs were similar for processed and unprocessed images for most parameters of interest with a few ICCs being higher or lower for processed images compared to unprocessed images. There is no strong evidence to suggest general beneficial effects of post-processing on ultrasound swallowing measurement reliability. These preliminary pilot data provide a foundation and directions for further research to clarify the role of ultrasound image post-processing for swallowing evaluation. Further refinement of processing methods may produce improved results.
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Imaging Studies II: Ultrasonography
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):